Evidence map›Paper›PMID 30790099›Full record

Trial reportAnnals of biomedical engineering2019

High-Resolution Body Surface Potential Mapping in Exercise Assessment of Ischemic Heart Disease.

Michał Kania, Roman Maniewski, Rajmund Zaczek, Małgorzata Kobylecka, Anna Zbieć, Leszek Królicki, Grzegorz Opolski

Open access · hybridAbstract readClinical Trial
In one paragraph

Trial report in Annals of biomedical engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Optimal ECG Lead System for Exercise Assessment of Ischemic Heart Disease.Journal of cardiovascular translational research · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Michał KaniaNalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Trojdena 4, 02-109, Warsaw, Poland. mkania@ibib.waw.pl.ORCID http://orcid.org/0000-0002-8857-6754
Roman ManiewskiNalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Trojdena 4, 02-109, Warsaw, Poland.
Rajmund ZaczekI Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Małgorzata KobyleckaDepartment of Nuclear Medicine, Medical University of Warsaw, Warsaw, Poland.
Anna ZbiećNalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Trojdena 4, 02-109, Warsaw, Poland.
Leszek KrólickiDepartment of Nuclear Medicine, Medical University of Warsaw, Warsaw, Poland.
Grzegorz OpolskiI Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
Medical University of Warsaw · PLInstitute of Biocybernetics and Biomedical Engineering · PL

Funding

Narodowe Centrum Nauki 2011/01/N/ST7/06690Narodowe Centrum Nauki NN 518 504 339
6 · The paper itself

Abstract

Standard 12-lead ECG exercise testing is commonly used for screening of ischemic heart disease (IHD). We studied if high-resolution body surface potential mapping (HR-BSPM) during exercise offers advantages over current standards in noninvasive evaluation of IHD. This study was carried out on 90 IHD patients and 33 healthy controls. The 67-lead HR-BSPM was recorded at rest and during exercise. Twenty-one ECG parameters including classical ST criteria were compared. The effectiveness of methods was verified based on the results of SPECT and coronary angiography. The most effective parameters in the diagnosis of IHD were: amplitude parameter ΔST60 and δT parameter showing T-wave morphology changes during exercise. The sensitivities/specificities of ΔST60 and δT parameters for the HR-BSPM were 70/69 and 59/62%, while for the standard 12-lead ECG system they were: 63/62 and 59/56%. These results demonstrate the usefulness of HR-BSPM measurements during exercise. HR-BSPM resulted in higher sensitivities and specificities compared to the standard 12-lead exercise test. The advantage was partially associated with observed ischemic changes outside standard precordial leads position that were not visible when using the standard 12-lead exercise test. This justifies research into the optimization of the number and position of ECG leads in exercise testing.

Indexed as

Body Surface Potential MappingCoronary AngiographyExercise TestSingle Photon Emission Computed Tomography Computed TomographyAdultAgedFemaleHumansMaleMiddle AgedMyocardial IschemiaCoronary angiographyExercise testHigh-resolution ECGMyocardial ischemiaSingle photon emission computed tomography

Identifiers

PMID30790099
PMCPMC6454081
OpenAlexW2915562096

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.