Evidence map›Paper›PMID 30786898›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2019

Quantification in cardiovascular magnetic resonance: agreement of software from three different vendors on assessment of left ventricular function, 2D flow and parametric mapping.

Leonora Zange, Fabian Muehlberg, Edyta Blaszczyk, Susanne Schwenke, Julius Traber, Stephanie Funk, Jeanette Schulz-Menger

Abstract readComparative Study
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

29 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Society for Cardiovascular Magnetic Resonance reference values ("normal values") in cardiovascular magnetic resonance: 2025 update.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025
    Guideline
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Multi-site comparison of parametric T1 and T2 mapping: healthy travelling volunteers in the Berlin research network for cardiovascular magnetic resonance (BER-CMR).Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Article
  20. Myocardial strain: a clinical review.Irish journal of medical science · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Leonora ZangeWorking Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Hospital Berlin-Buch, Department of Cardiology and Nephrology, Medical University Berlin, Charité Campus Buch, Lindenberger Weg 80, 13125, Berlin, Germany.
Fabian MuehlbergWorking Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Hospital Berlin-Buch, Department of Cardiology and Nephrology, Medical University Berlin, Charité Campus Buch, Lindenberger Weg 80, 13125, Berlin, Germany.
Edyta BlaszczykWorking Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Hospital Berlin-Buch, Department of Cardiology and Nephrology, Medical University Berlin, Charité Campus Buch, Lindenberger Weg 80, 13125, Berlin, Germany.
Susanne SchwenkeSCO:SSiS, Berlin, Germany.
Julius TraberWorking Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Hospital Berlin-Buch, Department of Cardiology and Nephrology, Medical University Berlin, Charité Campus Buch, Lindenberger Weg 80, 13125, Berlin, Germany.
Stephanie FunkWorking Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Hospital Berlin-Buch, Department of Cardiology and Nephrology, Medical University Berlin, Charité Campus Buch, Lindenberger Weg 80, 13125, Berlin, Germany.
Jeanette Schulz-MengerWorking Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Hospital Berlin-Buch, Department of Cardiology and Nephrology, Medical University Berlin, Charité Campus Buch, Lindenberger Weg 80, 13125, Berlin, Germany. Jeanette.schulz-menger@charite.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundQuantitative results of cardiovascular magnetic resonance (CMR) image analysis influence clinical decision making. Image analysis is performed based on dedicated software. The manufacturers provide different analysis tools whose algorithms are often unknown. The aim of this study was to evaluate the impact of software on quantification of left ventricular (LV) assessment, 2D flow measurement and T1- and T2-parametric mapping.

methodsThirty-one data sets of patients who underwent a CMR Scan on 1.5 T were analyzed using three different software (Circle CVI: cvi

resultsFor each parameter, thirty data sets could be analyzed with all three software. All three software (A/B, A/C, B/C) were considered equivalent for LV EF, EDV, ESV, mass, 2D flow SV and T2-time. Differences between software were detected in flow measurement for Vmax and in parametric mapping for T1-time. For Vmax, equivalence was given between software A and C and for T1-time equivalence was given between software B and C.

conclusionSoftware had no impact on quantitative results of LV assessment, T2-time and SV based on 2D flow. In contrast to that, Vmax and T1-time may be influenced by software. CMR reports should contain the name and version of the software applied for image analysis to avoid misinterpretation upon follow-up and research examinations.

trial registrationISRCTN12210850 . Registered 14 July 2017, retrospectively registered.

Indexed as

AlgorithmsSoftware DesignStroke VolumeVentricular Function, LeftAgedFemaleHeart DiseasesHumansImage Interpretation, Computer-AssistedMagnetic Resonance Imaging, CineMaleMiddle AgedObserver VariationPredictive Value of TestsReproducibility of Results2D flowAnalysisCardiovascular magnetic resonanceLeft ventricleParametric mappingPost-processing software

Identifiers

PMID30786898
PMCPMC6383230

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.