ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2020
Adding a protective K-wire during opening high tibial osteotomy increases lateral hinge resistance to fracture.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
29 citing papers in PubMed, 69 citations in OpenAlex.
- Reinforcement K-wires reduce the risk of tibial plateau and lateral cortex fractures during open wedge high tibial osteotomy: a prospective comparative cohort study.BMC musculoskeletal disorders · 2026Article
- Complications of osteotomies around the knee.Bulletin of the Hospital for Joint Disease (2013) · 2026Review
- Finite Element Investigation of Protective K-Wire Contribution to Hinge Fracture Prevention in Distal Femoral Osteotomy.Annals of biomedical engineering · 2026Article
- MRI-based classification of lateral hinge fractures in medial opening wedge high tibial osteotomy.Knee surgery & related research · 2026Article
- Reduced lateral hinge stress and fracture risk in double-hinge medial open-wedge high tibial osteotomy: A finite element study.Joint diseases and related surgery · 2026Article
- Medial Open-Wedge High Tibial Osteotomy for Double Varus Deformity and an Increased Tibial Slope.Arthroscopy techniques · 2025Article
- A single lateral hinge screw increased resistance to varus stress after medial closing wedge distal femoral osteotomy in a Sawbones model: A biomechanical analysis.Journal of experimental orthopaedics · 2025Article
- Evaluation of the effectiveness of Kirschner wires in preventing lateral hinge fractures in high tibial osteotomy: A finite element analysis.Joint diseases and related surgery · 2025Article
- The Sentinel Wires Technique for Safe Open Wedge High Tibial Osteotomy.Arthroscopy techniques · 2025Article
- Effects of K-wire diameter and insertion angle on femoral bone medial closing-wedge osteotomies: a finite element study.Scientific reports · 2025Article
- The effect of lateral hinge fracture with hinge hole and protective K-wire for medial opening-wedge high tibial osteotomy by compression testing and finite element analysis.Journal of orthopaedic surgery and research · 2025Article
- Percutaneous Hinge K-Wire and Screw in Osteotomy Around the Knee: A Technical Note.Arthroscopy techniques · 2025Article
- Is it beneficial to use lateral protective crossing K-wires during medial open wedge high tibial osteotomy? A retrospective comparative study.Journal of orthopaedic surgery and research · 2025Article
- Article
- How to Perform an Accurate and Safe Medial Open Wedge High Tibial Osteotomy; A Technical Note.The archives of bone and joint surgery · 2025Article
- Opening wedge high tibial osteotomy yields comparable to superior outcomes to unicompartmental knee arthroplasty at 2 years of follow-up in patients suffering from Ahlbäck III knee osteoarthritis: A propensity score-matched analysis.Journal of experimental orthopaedics · 2024Article
- Finite Element Analysis of Protective Measures against Lateral Hinge Fractures in High-Tibial Osteotomy.Advances in orthopedics · 2024Article
- Effect of lateral hinge fractures for bone union and clinical outcomes following opening-wedge distal tibial tubercle osteotomy in comparison with opening-wedge high tibial osteotomy.Journal of experimental orthopaedics · 2023Article
- A systematic approach to managing complications after proximal tibial osteotomies of the knee.Journal of experimental orthopaedics · 2023Review
- Corrective Osteotomies in Severe Non-Idiopathic Lower Limb Alignment Disorders in the Aspect of Future Joint Endoprosthesis-A Perspective Study.Journal of clinical medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIt was hypothesized in this in-vitro study that positioning a K-wire intersecting the cutting plane at the theoretical lateral hinge location would limit the cut depth and help preserve the lateral hinge during the opening of the osteotomy. Objectives were (1) to compare the mechanical resistance of the hinge and the protective effect of leaving the K-wire during the opening procedure (2) to check if the K-wire would limit the depth of the osteotomy.
methodsAn ex-vivo mechanical study, testing 5 pairs of fresh-frozen tibias, was designed. CT-scan based Patient-specific cutting guides were obtained to define the cutting plane and the location of the K-wire at the hinge, using standardized 3D planning protocol. In each pair, OWHTO was performed either with or without the K-wire. To evaluate the hinge's resistance to fracture, the specimens were rigidly fixed at the proximal tibia and a direct load was applied on the free tibial diaphysis to open the osteotomy. The maximum load at breakage, maximum permissible displacement and maximal angulation of the osteotomy before hinge failure was measured. To assess the preservation of an unscathed hinge (protected by the K-wire), the distance from the end of the osteotomy cut to the lateral tibial cortical was measured in mm.
resultsThe maximum load to hinge breakage in the K-wires PsCG knees compared to the control group (48.3 N vs 5.5 N, p = 0.004), the maximum permissible displacement (19.8 mm vs 7.5 mm, p = 0.005) and the maximal angulation of the osteotomy before hinge breakage (9.9° vs 2.9°, p = 0.002) were all statistically superior in the K-wires PsCG knees compared to the control group. A mean distance of 10 ± 1 mm between cut-bone (saw-print) and lateral hinge cortical bone was found post-performing the osteotomy and the hinge failing.
conclusionThe maximum load to breakage and the maximum permissible displacement were, respectively, 880% and 260% higher during the opening of the OWHTO in using K-wires compared to the non-K-wire control group. This confirms the mechanical advantage of using a K-wire for both stabilization and protecting the Hinge during OWHTO. This comparative cadaveric study shows an improvement of the lateral hinges resistance to failing during the opening of the osteotomy. This can be achieved by the placement of a K-wire intersecting the cutting plane at the theoretical location of the lateral hinge.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.