Evidence map›Paper›PMID 30782135›Full record

ArticleBMC bioinformatics2019

ElemCor: accurate data analysis and enrichment calculation for high-resolution LC-MS stable isotope labeling experiments.

Di Du, Lin Tan, Yumeng Wang, Bo Peng, John N Weinstein, Fredric E Wondisford, Xiaoyang Su, Philip L Lorenzi

Abstract read
In one paragraph

Article in BMC bioinformatics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Immature Acta2Nature communications · 2025
    Article
  6. Article
  7. Article
  8. Automated Assignment ofJournal of the American Society for Mass Spectrometry · 2024
    Article
  9. Article
  10. Mass spectrometry imaging ofFrontiers in plant science · 2024
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. AccuCor2: isotope natural abundance correction for dual-isotope tracer experiments.Laboratory investigation; a journal of technical methods and pathology · 2021
    Article
  17. Article
  18. Article
  19. mSystems · 2020
    Article
  20. Software tools, databases and resources in metabolomics: updates from 2018 to 2019.Metabolomics : Official journal of the Metabolomic Society · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Di DuDepartment of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.ORCID http://orcid.org/0000-0002-8851-8466
Lin TanDepartment of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
Yumeng WangDepartment of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
Bo PengDepartment of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
John N WeinsteinDepartment of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
Fredric E WondisfordDepartment of Medicine, Division of Endocrinology, Robert Wood Johnson Medical School, Rutgers University, New Brunswick, NJ, USA.
Xiaoyang SuDepartment of Medicine, Division of Endocrinology, Robert Wood Johnson Medical School, Rutgers University, New Brunswick, NJ, USA. xs137@rwjms.rutgers.edu.
Philip L LorenziDepartment of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA. pllorenzi@mdanderson.org.

Funding

Tumor Evolution and Metastasis ProgramP30CA016672 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI Scott Kopetz · 1985 to 2026
$290.8M
TRANSCRIPTIONAL PROFILINGP30CA072720 · NCI · UNIV OF MED/DENT NJ-R W JOHNSON MED SCH · PI Chang S Chan · 1997 to 2026
$94.5M
Transcriptional coactivators and hepatic glucose productionR01DK063349 · NIDDK · UNIVERSITY OF CHICAGO · PI WONDISFORD, FREDRIC E. · 2002 to 2017
$5.0M
Orbitrap Elite High-Resolution Mass Spectrometer for Proteomics and MetabolomicsS10OD012304 · OD · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI HAWKE, DAVID H · 2013 to 2013
$877k
Cancer Prevention and Research Institute of Texas RP130397National Institutes of Health 1S10OD012304-01National Institutes of Health P30 CA016672National Institutes of Health P30 CA072720NCI NIH HHS P30 CA016672NCI NIH HHS P30 CA072720NIDDK NIH HHS R01 DK063349NIH HHS S10 OD012304
6 · The paper itself

Abstract

backgroundThe investigation of intracellular metabolism is the mainstay in the biotechnology and physiology settings. Intracellular metabolic rates are commonly evaluated using labeling pattern of the identified metabolites obtained from stable isotope labeling experiments. The labeling pattern or mass distribution vector describes the fractional abundances of all isotopologs with different masses as a result of isotopic labeling, which are typically resolved using mass spectrometry. Because naturally occurring isotopes and isotopic impurity also contribute to measured signals, the measured patterns must be corrected to obtain the labeling patterns. Since contaminant isotopologs with the same nominal mass can be resolved using modern mass spectrometers with high mass resolution, the correction process should be resolution dependent.

resultsHere we present a software tool, ElemCor, to perform correction of such data in a resolution-dependent manner. The tool is based on mass difference theory (MDT) and information from unlabeled samples (ULS) to account for resolution effects. MDT is a mathematical theory and only requires chemical formulae to perform correction. ULS is semi-empirical and requires additional measurement of isotopologs from unlabeled samples. We validate both methods and show their improvement in accuracy and comprehensiveness over existing methods using simulated data and experimental data from Saccharomyces cerevisiae. The tool is available at https://github.com/4dsoftware/elemcor .

conclusionsWe present a software tool based on two methods, MDT and ULS, to correct LC-MS data from isotopic labeling experiments for natural abundance and isotopic impurity. We recommend MDT for low-mass compounds for cost efficiency in experiments, and ULS for high-mass compounds with relatively large spectral inaccuracy that can be tracked by unlabeled standards.

Indexed as

Data AnalysisSoftwareChromatography, LiquidComputer SimulationIsotope LabelingIsotopesMass SpectrometrySaccharomyces cerevisiaeIsotopesData correctionHigh resolutionLC-MSStable isotope labeling

Identifiers

PMID30782135
PMCPMC6381631

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.