Evidence map›Paper›PMID 30781666›Full record

ArticleMicromachines2019

An Experimental Study of 3D Electrode-Facilitated Particle Traffic Flow-Focusing Driven by Induced-Charge Electroosmosis.

Tianyi Jiang, Ye Tao, Hongyuan Jiang, Weiyu Liu, Yansu Hu, Dewei Tang

Abstract read
In one paragraph

Article in Micromachines, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tianyi JiangState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China. jty_hit@hit.edu.cn.
Ye TaoState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China. tarahit@gmail.com.
Hongyuan JiangState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China. jhy_hit@hit.edu.cn.
Weiyu LiuSchool of Electronics and Control Engineering, Chang'an University, Xi'an 710064, China. liuweiyu@chd.edu.cn.ORCID 0000-0003-2503-4525
Yansu HuSchool of Electronics and Control Engineering, Chang'an University, Xi'an 710064, China. huyansu@chd.edu.cn.
Dewei TangState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China. dwtang@hit.edu.cn.

Funding

National Natural Science Foundation of China 11702035
6 · The paper itself

Abstract

In this paper we present a novel microfluidic approach for continuous, rapid and switchable particle concentration, using induced-charge electroosmosis (ICEO) in 3D electrode layouts. Field-effect control on non-linear electroosmosis in the transverse direction greatly facilitates a selective concentration of biological yeast cells from a straight main microchannel into one of the three downstream branch channels in our microfluidic device. For the geometry configuration of 3D driving electrode plates on sidewalls and a 2D planar gate electrode strip on the channel bottom surface, we briefly describe the underlying physics of an ICEO-based particle flow-focusing method, and provide relevant simulation results to show how gate voltage amplitude can be used to guide the motion trajectory of the concentrated particle stream. With a relatively simple geometrical configuration, the proposed microfluidic device provides new possibilities to controllably concentrate micro/nanoparticles in continuous flow by using ICEO, and is suitable for a high-throughput front-end cell concentrator interfacing with various downstream biosensors.

Indexed as

composite electrode arrangementcontinuous and switchable particle flow-focusingfield-effect flow controlinduced-charge electroosmosismicrofluidic particle concentrator

Identifiers

PMID30781666
PMCPMC6412237

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.