Robust CT ventilation from the integral formulation of the Jacobian.

Edward Castillo, Richard Castillo, Yevgeniy Vinogradskiy, Michele Dougherty, David Solis, Nicholas Myziuk, Andrew Thompson, Rudy Guerra, Girish Nair, Thomas Guerrero

Abstract read
In one paragraph

Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Edward CastilloDepartment of Radiation Oncology, Beaumont Health Systems, Royal Oak, MI, USA.
Richard CastilloDepartment of Radiation Oncology, Emory University, Atlanta, GA, USA.
Yevgeniy VinogradskiyDepartment of Radiation Oncology, University of Colorado, Denver, CO, USA.
Michele DoughertyDepartment of Radiation Oncology, Mayo Clinic, Rochester, MN, USA.
David SolisDepartment of Radiation Oncology, Beaumont Health Systems, Royal Oak, MI, USA.
Nicholas MyziukDepartment of Radiation Oncology, Beaumont Health Systems, Royal Oak, MI, USA.
Andrew ThompsonDepartment of Radiation Oncology, Beaumont Health Systems, Royal Oak, MI, USA.
Rudy GuerraDepartment of Statistics, Rice University, Houston, TX, USA.
Girish NairDepartment of Internal Medicine, Beaumont Health Systems, Royal Oak, MI, USA.
Thomas GuerreroDepartment of Radiation Oncology, Beaumont Health Systems, Royal Oak, MI, USA.

Funding

Clinical trial personalizing radiation therapy through a novel lung function imaging modalityR01CA200817 · NCI · UNIVERSITY OF COLORADO DENVER · PI VINOGRADSKIY, YEVGENIY · 2016 to 2018
$618k
NCI NIH HHS R01 CA200817NIH HHS R01CA200817
6 · The paper itself

Abstract

Computed tomography (CT) derived ventilation algorithms estimate the apparent voxel volume changes within an inhale/exhale CT image pair. Transformation-based methods compute these estimates solely from the spatial transformation acquired by applying a deformable image registration (DIR) algorithm to the image pair. However, approaches based on finite difference approximations of the transformation's Jacobian have been shown to be numerically unstable. As a result, transformation-based CT ventilation is poorly reproducible with respect to both DIR algorithm and CT acquisition method. PURPOSE: We introduce a novel Integrated Jacobian Formulation (IJF) method for estimating voxel volume changes under a DIR-recovered spatial transformation. The method is based on computing volume estimates of DIR mapped subregions using the hit-or-miss sampling algorithm for integral approximation. The novel approach allows for regional volume change estimates that (a) respect the resolution of the digital grid and (b) are based on approximations with quantitatively characterized and controllable levels of uncertainty. As such, the IJF method is designed to be robust to variations in DIR solutions and thus overall more reproducible.

methodsNumerically, Jacobian estimates are recovered by solving a simple constrained linear least squares problem that guarantees the recovered global volume change is equal to the global volume change obtained from the inhale and exhale lung segmentation masks. Reproducibility of the IJF method with respect to DIR solution was assessed using the expert-determined landmark point pairs and inhale/exhale phases from 10 four-dimensional computed tomographies (4DCTs) available on www.dir-lab.com. Reproducibility with respect to CT acquisition was assessed on the 4DCT and 4D cone beam CT (4DCBCT) images acquired for five lung cancer patients prior to radiotherapy.

resultsThe ten Dir-Lab 4DCT cases were registered twice with the same DIR algorithm, but with different smoothing parameter. Finite difference Jacobian (FDJ) and IFJ images were computed for both solutions. The average spatial errors (300 landmarks per case) for the two DIR solution methods were 0.98 (1.10) and 1.02 (1.11). The average Pearson correlation between the FDJ images computed from the two DIR solutions was 0.83 (0.03), while for the IJF images it was 1.00 (0.00). For intermodality assessment, the IJF and FDJ images were computed from the 4DCT and 4DCBCT of five patients. The average Pearson correlation of the spatially aligned FDJ images was 0.27 (0.11), while it was 0.77 (0.13) for the IFJ method.

conclusionThe mathematical theory underpinning the IJF method allows for the generation of ventilation images that are (a) computed with respect to DIR spatial accuracy on the digital voxel grid and (b) based on DIR-measured subregional volume change estimates acquired with quantifiable and controllable levels of uncertainty. Analyses of the experiments are consistent with the mathematical theory and indicate that IJF ventilation imaging has a higher reproducibility with respect to both DIR algorithm and CT acquisition method, in comparison to the standard finite difference approach.

Indexed as

AlgorithmsPulmonary VentilationCarcinoma, Non-Small-Cell LungCone-Beam Computed TomographyFour-Dimensional Computed TomographyHumansLung NeoplasmsRadiographic Image Interpretation, Computer-AssistedRespirationRetrospective Studies4DCTcomputed tomographycone beam CTdeformable image registrationventilation

Identifiers

PMID30779353
PMCPMC6510605

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.