Evidence map›Paper›PMID 30779022›Full record

ArticleInternational journal of computer assisted radiology and surgery2019

An analytical approach for the simulation of realistic low-dose fluoroscopic images.

Sai Gokul Hariharan, Norbert Strobel, Christian Kaethner, Markus Kowarschik, Rebecca Fahrig, Nassir Navab

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sai Gokul HariharanComputer Aided Medical Procedures, Technische Universität München, Munich, Germany. saigokul.hariharan@tum.de.ORCID http://orcid.org/0000-0002-4446-6799
Norbert StrobelSiemens Healthineers AG, Advanced Therapies, Forchheim, Germany.
Christian KaethnerSiemens Healthineers AG, Advanced Therapies, Forchheim, Germany.
Markus KowarschikComputer Aided Medical Procedures, Technische Universität München, Munich, Germany.
Rebecca FahrigSiemens Healthineers AG, Advanced Therapies, Forchheim, Germany.
Nassir NavabComputer Aided Medical Procedures, Technische Universität München, Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe quality of X-ray images plays an important role in computer-assisted interventions. Although learning-based denoising techniques have been shown to be successful in improving the image quality, they often rely on pairs of associated low- and high-dose X-ray images that are usually not possible to acquire at different dose levels in a clinical scenario. Moreover, since data variation is an important requirement for learning-based methods, the use of phantom data alone may not be sufficient. A possibility to address this issue is a realistic simulation of low-dose images from their related high-dose counterparts.

methodWe introduce a novel noise simulation method based on an X-ray image formation model. The method makes use of the system parameters associated with low- and high-dose X-ray image acquisitions, such as system gain and electronic noise, to preserve the image noise characteristics of low-dose images.

resultsWe have compared several corresponding regions of the associated real and simulated low-dose images-obtained from two different imaging systems-visually as well as statistically, using a two-sample Kolmogorov-Smirnov test at 5% significance. In addition to being visually similar, the hypothesis that the corresponding regions-from 80 pairs of real and simulated low-dose regions-belonging to the same distribution has been accepted in 81.43% of the cases.

conclusionThe results suggest that the simulated low-dose images obtained using the proposed method are almost indistinguishable from real low-dose images. Since extensive calibration procedures required in previous methods can be avoided using the proposed approach, it allows an easy adaptation to different X-ray imaging systems. This in turn leads to an increased diversity of the training data for potential learning-based methods.