Evidence map›Paper›PMID 30777036›Full record

ArticleBMC pulmonary medicine2019

Impact of leaks and ventilation parameters on the efficacy of humidifiers during home ventilation for tracheostomized patients: a bench study.

Noémie Haziot, Mohamed Ibrahim, Kaixian Zhu, Charles-Philippe Thevenin, Sebastien Hardy, Jésus Gonzalez-Bermejo

Abstract read
In one paragraph

Article in BMC pulmonary medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Noémie HaziotService de Pneumologie et Réanimation Médicale (Département "R3S")AP-HP, Groupe Hospitalier Pitié-Salpêtrière Charles Foix, 47-83 boulevard de l'hôpital, F-75013, Paris, France. noemie.haziot@aphp.fr.ORCID http://orcid.org/0000-0001-6002-9807
Mohamed IbrahimAir Liquide Healthcare (EXPLOR Center), Gentilly, France.
Kaixian ZhuAir Liquide Healthcare (EXPLOR Center), Gentilly, France.
Charles-Philippe TheveninAir Liquide Healthcare (EXPLOR Center), Gentilly, France.
Sebastien HardyAir Liquide Healthcare (EXPLOR Center), Gentilly, France.
Jésus Gonzalez-BermejoService de Pneumologie et Réanimation Médicale (Département "R3S")AP-HP, Groupe Hospitalier Pitié-Salpêtrière Charles Foix, 47-83 boulevard de l'hôpital, F-75013, Paris, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDuring invasive ventilation, the upper airway is bypassed and no longer participates in humidification of inspired gases, which is essential to avoid harmful consequences such as endotracheal tube occlusion. In the case of increased air flow, especially in the presence of leaks (intentional or unintentional), the humidification provided by humidifiers may become ineffective. The objective of this bench study was to evaluate the quality of humidification provided by heated humidifiers under various home ventilation conditions.

methodsFive heated humidifiers were tested in eight configurations combining circuit (expiratory valve or vented circuit), tidal volume (600 or 1000 mL) and presence of unintentional leak. Absolute humidity (AH) was measured at the upstream of the test lungs, which were placed in a 34 °C environmental chamber in order to simulate body temperature.

resultsThe AH measured in the valve circuit ranged between 30 mg/L and 40 mg/L and three out of the five humidifiers achieved an AH higher than the recommended level (33 mg/L). With the vented circuit without unintentional leak, when tidal volume was set at 600 mL, all humidifiers reached an AH higher than 33 mg/L except one device; when the tidal volume was set at 1000 mL and unintentional leak was present, four out of the five humidifiers provided an AH lower than 33 mg/L.

conclusionThis study shows that, except under certain home ventilation conditions, such as high tidal volumes with unintentional leak in vented circuit, most heated humidifiers ensure sufficient humidification to avoid the risk of side effect in patients.

Indexed as

Home Care ServicesHumidifiersHumidityTidal VolumeHot TemperatureHumansIn Vitro TechniquesRespiration, ArtificialTracheostomyArtificialBench testHeated humidifierHumidificationInvasive ventilationRespirationRespiratory therapyTracheostomyUnintentional leakVented circuit

Identifiers

PMID30777036
PMCPMC6379988

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.