Evidence map›Paper›PMID 30776287›Full record

SynthesisMedical science monitor : international medical journal of experimental and clinical research2019

Dynamic Fixation Versus Static Fixation for Distal Tibiofibular Syndesmosis Injuries: A Meta-Analysis.

Kaifeng Gan, Ke Zhou, Keqi Hu, Liangjie Lu, Shirong Gu, Yandong Shen

Open access · hybridAbstract readMeta-Analysis
In one paragraph

Synthesis in Medical science monitor : international medical journal of experimental and clinical research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
2.3field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 24 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Management of Syndesmosis Injury: A Narrative Review.Orthopedic research and reviews · 2022
    Review
  12. Article
  13. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Kaifeng GanDepartment of Orthopaedics, Ningbo Medical Center Lihuili Hospital, Ningbo, Zhejiang, China (mainland).
Ke ZhouDepartment of Orthopaedics, Ningbo Medical Center Lihuili Hospital, Ningbo, Zhejiang, China (mainland).
Keqi HuDepartment of Orthopaedics, Ningbo Medical Center Lihuili Hospital, Ningbo, Zhejiang, China (mainland).
Liangjie LuDepartment of Orthopaedics, Ningbo Medical Center Lihuili Hospital, Ningbo, Zhejiang, China (mainland).
Shirong GuDepartment of Orthopaedics, Ningbo Medical Center Lihuili Hospital, Ningbo, Zhejiang, China (mainland).
Yandong ShenDepartment of Orthopaedics, Ningbo Medical Center Lihuili Hospital, Ningbo, Zhejiang, China (mainland).
Ningbo Medical Center Lihuili Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND Ankle sprains with distal tibiofibular syndesmosis injuries (DTSIs) require anatomic reduction and fixation to restore the normal biomechanics of the ankle joint. In the last decade, dynamic fixation (DF) for DTSIs using a suture-button device has gained popularity because of its advantages over static fixation (SF). MATERIAL AND METHODS The present meta-analysis was conducted to compare clinical outcomes between DF and SF of DTSIs. PubMed, Cochrane Central Register of Controlled Trials, and Embase were systematically searched. Three randomized controlled studies and 7 cohort studies, with a total of 420 patients, were involved in this study. DTSIs patients treated with DF were assigned to the experimental group, and patients treated with SF were assigned to the control group. Outcomes were evaluated and analyzed by using review-manager software. Mean difference (MD) or risk ratio (RR) with 95% confidence interval (95% CI) was analyzed and calculated by utilizing the random effects models. RESULTS Analysis revealed no statistically significant differences between DF and SF in American Orthopedic Foot and Ankle Society Ankle-Hindfoot score (MD, 1.90; 95% CI, -0.23-4.03; p=0.08; I²=0%), Olerud-Molander score (MD, 1.92; 95% CI, -7.96-11.81; p=0.70; I²=55%), incidence of syndesmotic malreduction (RR, 0.19; 95% CI, 0.03-1.09; p=0.06; I²=0%), and overall postoperative complication rate (RR, 0.30; 95% CI, 0.09-0.99; p=0.05, I²=75%). The rate of second procedure was significantly lower compared with DF (RR, 0.17; 95% CI, 0.07-0.43; p=0.0002, I²=54%). CONCLUSIONS The dynamic fixation and static fixation methods are equal in clinical outcomes, with dynamic fixation needing fewer second interventions for DTSIs.

Indexed as

AdultAnkle InjuriesAnkle JointBone ScrewsChinaFemaleFracture Fixation, InternalHumansMaleTreatment Outcome

Identifiers

PMID30776287
PMCPMC6392477
OpenAlexW2916306833

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.