ArticleBiomedical optics express2019
Real-time compensation method for robust polarimetric determination of glucose in turbid media.
Article in Biomedical optics express, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- A low-power approach to optical glucose sensing via polarisation switching.Scientific reports · 2025Article
- Non-invasive glucose extraction by a single polarization rotator system in patients with diabetes.Biomedical optics express · 2024Article
- [Research progress on minimally invasive and non-invasive blood glucose detection methods].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2023Article
- Non-Invasive Blood Glucose Monitoring Technology: A Review.Sensors (Basel, Switzerland) · 2020Review
- Review of Non-invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone.Sensors (Basel, Switzerland) · 2020Review
- Broadband polarimetric glucose determination in protein containing media using characteristic optical rotatory dispersion.Biomedical optics express · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Polarimetric determination of glucose is known to be strongly affected by scattering in turbid media. Other effects like fluctuations of light source emission and sample absorption also deteriorate glucose predictability. This work presents a measurement setup using a real-time data processing method to address these problems. The approach uses the frequency-dependent intensity components created when the polarization of the incident light is periodically modulated by a Faraday rotator. The efficacy of the proposed method was verified experimentally for a glucose range of 0 - 500 mg/dl. It was shown that the approach reduces the prediction errors in slightly turbid media from 35.7 mg/dl down to 1.17 mg/dl. In a similar way, the glucose predictability for fluctuating light source emission was improved from ±16.16 mg/dl to ±1 mg/dl and for varying sample absorbance from ±15.69 mg/dl to ±1.23 mg/dl, respectively. Therefore, considerable improvement of robustness and reproducibility of glucose determination was demonstrated.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.