Evidence map›Paper›PMID 30765527›Full record

ArticleProceedings of the National Academy of Sciences of the United States of America2019

Three-dimensional optical trapping and orientation of microparticles for coherent X-ray diffraction imaging.

Yuan Gao, Ross Harder, Stephen H Southworth, Jeffrey R Guest, Xiaojing Huang, Zijie Yan, Leonidas E Ocola, Yuval Yifat, Nishant Sule, Phay J Ho and 3 more

Abstract read
In one paragraph

Article in Proceedings of the National Academy of Sciences of the United States of America, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Yuan GaoChemical Sciences & Engineering Division, Argonne National Laboratory, Lemont, IL 60439; yuangao@bnl.gov young@anl.gov.
Ross HarderAdvanced Photon Source, Argonne National Laboratory, Lemont, IL 60439.
Stephen H SouthworthChemical Sciences & Engineering Division, Argonne National Laboratory, Lemont, IL 60439.
Jeffrey R GuestCenter for Nanoscale Materials, Argonne National Laboratory, Lemont, IL 60439.
Xiaojing HuangNational Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973.
Zijie YanJames Franck Institute, The University of Chicago, Chicago, IL 60637.
Leonidas E OcolaCenter for Nanoscale Materials, Argonne National Laboratory, Lemont, IL 60439.
Yuval YifatJames Franck Institute, The University of Chicago, Chicago, IL 60637.
Nishant SuleJames Franck Institute, The University of Chicago, Chicago, IL 60637.
Phay J HoChemical Sciences & Engineering Division, Argonne National Laboratory, Lemont, IL 60439.
Matthew PeltonDepartment of Physics, University of Maryland, Baltimore County (UMBC), Baltimore, MD 21250.
Norbert F SchererCenter for Nanoscale Materials, Argonne National Laboratory, Lemont, IL 60439.
Linda YoungChemical Sciences & Engineering Division, Argonne National Laboratory, Lemont, IL 60439; yuangao@bnl.gov young@anl.gov.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optical trapping has been implemented in many areas of physics and biology as a noncontact sample manipulation technique to study the structure and dynamics of nano- and mesoscale objects. It provides a unique approach for manipulating microscopic objects without inducing undesired changes in structure. Combining optical trapping with hard X-ray microscopy techniques, such as coherent diffraction imaging and crystallography, provides a nonperturbing environment where electronic and structural dynamics of an individual particle in solution can be followed in situ. It was previously shown that optical trapping allows the manipulation of micrometer-sized objects for X-ray fluorescence imaging. However, questions remain over the ability of optical trapping to position objects for X-ray diffraction measurements, which have stringent requirements for angular stability. Our work demonstrates that dynamic holographic optical tweezers are capable of manipulating single micrometer-scale anisotropic particles in a microfluidic environment with the precision and stability required for X-ray Bragg diffraction experiments-thus functioning as an "optical goniometer." The methodology can be extended to a variety of X-ray experiments and the Bragg coherent diffractive imaging of individual particles in solution, as demonstrated here, will be markedly enhanced with the advent of brighter, coherent X-ray sources.

Indexed as

Microfluidic Analytical TechniquesOptical TweezersParticle SizeX-Ray Diffractioncoherent X-ray diffraction imagingmicrofluidicnanoscienceoptical trappingoptical tweezers

Identifiers

PMID30765527
PMCPMC6410780

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.