Evidence map›Paper›PMID 30760731›Full record

ArticleScientific reports2019

Clinical Potential of a New Approach to MRI Acceleration.

Nadine L Dispenza, Sebastian Littin, Maxim Zaitsev, R Todd Constable, Gigi Galiana

Abstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Group-Patch Joint Compression: Compressing Dynamic BMagnetic resonance in medicine · 2026
    Article
  2. Article
  3. Article
  4. 3D FRONSAC with PSF reconstruction.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2023
    Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Nadine L DispenzaDepartment of Biomedical Engineering, Yale University, New Haven, CT, USA.
Sebastian LittinDepartment of Diagnostic Radiology, Medical Physics, University Medical Center Freiburg, Breisacher Str. 60a, 79106, Freiburg, Germany.ORCID 0000-0002-8190-1761
Maxim ZaitsevDepartment of Diagnostic Radiology, Medical Physics, University Medical Center Freiburg, Breisacher Str. 60a, 79106, Freiburg, Germany.
R Todd ConstableDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06520, USA.ORCID 0000-0001-5661-9521
Gigi GalianaDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06520, USA. gigi.galiana@yale.edu.

Funding

Null Space Imaging - A Novel Approach to Accelerating MR ImagingR01EB012289 · NIBIB · YALE UNIVERSITY · PI CONSTABLE, R TODD · 2010 to 2014
$3.3M
O-Space Imaging - Accelerating MRI with Z2 Gradient EncodingR01EB016978 · NIBIB · YALE UNIVERSITY · PI CONSTABLE, R TODD · 2013 to 2016
$2.0M
Practical Nonlinear Gradient Encoding for Enhanced Accelerated ImagingR01EB022030 · NIBIB · YALE UNIVERSITY · PI GALIANA, GIGI · 2017 to 2020
$1.5M
NIBIB NIH HHS R01 EB012289NIBIB NIH HHS R01 EB016978NIBIB NIH HHS R01 EB022030U.S. Department of Health & Human Services | National Institutes of Health (NIH) K01EB168977
6 · The paper itself

Abstract

Fast ROtary Nonlinear Spatial ACquisition (FRONSAC) was recently introduced as a new strategy that applies nonlinear gradients as a small perturbation to improve image quality in highly undersampled MRI. In addition to experimentally showing the previously simulated improvement to image quality, this work introduces the insight that Cartesian-FRONSAC retains many desirable features of Cartesian imaging. Cartesian-FRONSAC preserves the existing linear gradient waveforms of the Cartesian sequence while adding oscillating nonlinear gradient waveforms. Experiments show that performance is essentially identical to Cartesian imaging in terms of (1) resilience to experimental imperfections, like timing errors or off-resonance spins, (2) accommodating scan geometry changes without the need for recalibration or additional field mapping, (3) contrast generation, as in turbo spin echo. Despite these similarities to Cartesian imaging, which provides poor parallel imaging performance, Cartesian-FRONSAC consistently shows reduced undersampling artifacts and better response to advanced reconstruction techniques. A final experiment shows that hardware requirements are also flexible. Cartesian-FRONSAC improves accelerated imaging while retaining the robustness and flexibility critical to real clinical use.

Indexed as

BrainHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingPhantoms, Imaging

Identifiers

PMID30760731
PMCPMC6374397

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked