Evidence map›Paper›PMID 30760723›Full record

ArticleNature communications2019

A three-dimensional ratiometric sensing strategy on unimolecular fluorescence-thermally activated delayed fluorescence dual emission.

Xuping Li, Gleb Baryshnikov, Chao Deng, Xiaoyan Bao, Bin Wu, Yunyun Zhou, Hans Ågren, Liangliang Zhu

Abstract read
In one paragraph

Article in Nature communications, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Asymmetrically bridged aroyl-Chemical science · 2022
    Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xuping LiState Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China.
Gleb BaryshnikovDivision of Theoretical Chemistry and Biology School of Biotechnology, KTH Royal Institute of Technology, SE-10691, Stockholm, Sweden.ORCID http://orcid.org/0000-0002-0716-3385
Chao DengMOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou, 310027, China.
Xiaoyan BaoState Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China.
Bin WuState Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China.
Yunyun ZhouState Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China.
Hans ÅgrenDivision of Theoretical Chemistry and Biology School of Biotechnology, KTH Royal Institute of Technology, SE-10691, Stockholm, Sweden.
Liangliang ZhuState Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China. zhuliangliang@fudan.edu.cn.ORCID http://orcid.org/0000-0001-6268-3351

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Visualized sensing through fluorescence signals is a powerful method for chemical and physical detection. However, the utilization of fluorescent molecular probes still suffers from lack of precise signal self-calibration in practical use. Here we show that fluorescence and thermally activated delayed fluorescence can be simultaneously produced at the single-molecular level. The thermally activated delayed fluorescence serves as a sensing signal with its wavelength and lifetime both altered correlating to polarity, whereas the fluorescence always remains unchanged as an internal reference. Upon the establishment of a three-dimensional working curve upon the ratiometric wavelength and photoluminescence lifetime vs. polarity, disturbance factors during a relevant sensing process can be largely minimized by such a multiple self-calibration. This strategy was further applied into a precise detection of the microenvironmental polarity variation in complex phospholipid systems, towards providing new insights for convenient and accurate diagnosis of membrane lesions.

Identifiers

PMID30760723
PMCPMC6374486

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.