ArticleThe American journal of case reports2019
Use of 3D Volume Rendering Based on High-Resolution Computed Tomography Temporal Bone in Patients with Cochlear Implants.
Article in The American journal of case reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 18 citations in OpenAlex.
- The SmARTR pipeline: A modular workflow for the cinematic rendering of 3D scientific imaging data.iScience · 2024Article
- Advances in 3D Inner Ear Reconstruction Software for Cochlear Implants: A Comprehensive Review.Methods and protocols · 2024Review
- Implantation of the Vibrant Soundbridge in a Case of Bilateral Malformation of the Middle and External Ear.The American journal of case reports · 2021Article
- Multimodal Imaging in Susac Syndrome: A Case Report and Literature Review.International journal of environmental research and public health · 2021Review
- Titanium and Platinum-Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography.Life (Basel, Switzerland) · 2021Article
- Cochlear Implant Surgery: Endomeatal Approach versus Posterior Tympanotomy.International journal of environmental research and public health · 2020Article
- Real ear measurement (REM) and auditory performances with open, tulip and double closed dome in patients using hearing aids.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2020Article
- Application of Cervical Vestibular-Evoked Myogenic Potentials in Adults with Moderate to Profound Sensorineural Hearing Loss: A Preliminary Study.International archives of otorhinolaryngology · 2020Article
- Vocal cord surgery and pharmacological treatment of a patient with HPV and recurrent respiratory papillomatosis.BMJ case reports · 2019Article
- The Additional Diagnostic Value of the Three-dimensional Volume Rendering Imaging in Routine Radiology Practice.Cureus · 2019Review
- Hyperbaric oxygen therapy in a case of cervical abscess extending to anterior mediastinum, with isolation ofBMJ case reports · 2019Article
- Endomeatal approach in cochlear implant surgery in a patient with small mastoid cavity and procident lateral sinus.BMJ case reports · 2019Article
- Endoscopic treatment of a periorbital fat herniation caused by spontaneous solution of continuity of the papyracea lamina.BMJ case reports · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND The purpose of this study is to demonstrate the advantages of 3D volume rendering in postoperative control of implants placement compared to high-resolution computed tomography (HRCT). CASE REPORT We describe 3 patients who underwent HRCT study with and without 3D volume rendering after surgery for cochlear implantation. In 2 patients, the traditional HRCT showed a suspected malposition of the array, excluded only by the rendering reconstruction. In the other patient, thanks to the 3D rendering, we were able to identify the complete migration of the array out of the cochlea and the tip of the electrode near the opening of internal auditory canal, while the traditional images showed only that the array was not rolled up inside the cochlea. CONCLUSIONS HRCT showed complex anatomic structures of the inner ear and contents of the middle ear cavity. The volume rendering, in the postoperative control, generates interactive 3D images of the cochlear implant, facilitating a clearer representation of the topographic complex of the cochlea, giving more detailed diagnostic information than the HRCT.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.