ArticlePloS one2019
Feasibility of multiple-view myocardial perfusion MRI using radial simultaneous multi-slice acquisitions.
Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed.
- Dynamic Mode Decomposition (DMD) for Low-Latency Real-Time Cardiac MRI.Magnetic resonance in medicine · 2026Article
- K-CC-MoCo: A Fast k-Space-Based Respiratory Motion Correction for Highly Accelerated First-Pass Perfusion Cardiovascular MR.Magnetic resonance in medicine · 2026Article
- Online Spatiotemporally Constrained Reconstruction for Real-Time Interactive MRI.Magnetic resonance in medicine · 2026Article
- Improving ungated steady-state cardiac perfusion using transition bands.Magnetic resonance in medicine · 2025Article
- Free-Breathing Ungated Radial Simultaneous Multi-Slice Cardiac T1 Mapping.Journal of magnetic resonance imaging : JMRI · 2025Article
- Simultaneous multi-slice cardiac real-time MRI at 0.55T.Magnetic resonance in medicine · 2025Article
- Quantitative myocardial perfusion with a hybrid 2D simultaneous multi-slice sequence.Magnetic resonance imaging · 2023Article
- Contrast-optimal simultaneous multi-slice bSSFP cine cardiac imaging at 0.55 T.Magnetic resonance in medicine · 2023Article
- A Slice-Low-Rank Plus Sparse (slice-L + S) Reconstruction Method for k-t Undersampled Multiband First-Pass Myocardial Perfusion MRI.Magnetic resonance in medicine · 2022Article
- Simultaneous multislice steady-state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T.Magnetic resonance in medicine · 2022Article
- Deep learning for radial SMS myocardial perfusion reconstruction using the 3D residual booster U-net.Magnetic resonance imaging · 2021Article
- Aliasing artifact reduction in spiral real-time MRI.Magnetic resonance in medicine · 2021Article
- All-systolic first-pass myocardial rest perfusion at a long saturation time using simultaneous multi-slice imaging and compressed sensing acceleration.Magnetic resonance in medicine · 2021Article
- Improved simultaneous multislice cardiac MRI using readout concatenated k-space SPIRiT (ROCK-SPIRiT).Magnetic resonance in medicine · 2021Article
- Whole-heart, ungated, free-breathing, cardiac-phase-resolved myocardial perfusion MRI by using Continuous Radial Interleaved simultaneous Multi-slice acquisitions at sPoiled steady-state (CRIMP).Magnetic resonance in medicine · 2020Article
- Combined simultaneous multislice bSSFP and compressed sensing for first-pass myocardial perfusion at 1.5 T with high spatial resolution and coverage.Magnetic resonance in medicine · 2020Article
- Iterative versus non-iterative image reconstruction methods for sparse magnetic resonance imaging.Journal of radiology and imaging · 2020Article
- Non-iterative image reconstruction from sparse magnetic resonance imaging radial data without priors.Visual computing for industry, biomedicine, and art · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
purposeDynamic contrast enhanced MRI of the heart typically acquires 2-4 short-axis (SA) slices to detect and characterize coronary artery disease. This acquisition scheme is limited by incomplete coverage of the left ventricle. We studied the feasibility of using radial simultaneous multi-slice (SMS) technique to achieve SA, 2-chamber and/or 4-chamber long-axis (2CH LA and/or 4CH LA) coverage with and without electrocardiography (ECG) gating using a motion-robust reconstruction framework.
methods12 subjects were scanned at rest and/or stress, free breathing, with or without ECG gating. Multiple sets of radial SMS k-space were acquired within each cardiac cycle, and each SMS set sampled 3 parallel slices that were either SA, 2CH LA, or 4CH LA slices. The radial data was interpolated onto Cartesian space using an SMS GRAPPA operator gridding method. Self-gating and respiratory states binning of the data were done. The binning information as well as a pixel tracking spatiotemporal constrained reconstruction method were applied to obtain motion-robust image reconstructions. Reconstructions with and without the pixel tracking method were compared for signal-to-noise ratio and contrast-to-noise ratio.
resultsFull coverage of the heart (at least 3 SA and 3 LA slices) during the first pass of contrast at every heartbeat was achieved by using the radial SMS acquisition. The proposed pixel tracking reconstruction improves the average SNR and CNR by 21% and 30% respectively, and reduces temporal blurring for both gated and ungated acquisitions.
conclusionAcquiring simultaneous multi-slice SA, 2CH LA and/or 4CH LA myocardial perfusion images in every heartbeat is feasible in both gated and ungated acquisitions. This can add confidence when detecting and characterizing coronary artery disease by revealing ischemia in different views, and by providing apical coverage that is improved relative to SA slices alone. The proposed pixel tracking framework improves the reconstruction while adding little computational cost.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.