Evidence map›Paper›PMID 30742641›Full record

ArticlePloS one2019

Feasibility of multiple-view myocardial perfusion MRI using radial simultaneous multi-slice acquisitions.

Ye Tian, Jason Mendes, Apoorva Pedgaonkar, Mark Ibrahim, Leif Jensen, Joyce D Schroeder, Brent Wilson, Edward V R DiBella, Ganesh Adluru

Abstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Free-Breathing Ungated Radial Simultaneous Multi-Slice Cardiac T1 Mapping.Journal of magnetic resonance imaging : JMRI · 2025
    Article
  6. Simultaneous multi-slice cardiac real-time MRI at 0.55T.Magnetic resonance in medicine · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Aliasing artifact reduction in spiral real-time MRI.Magnetic resonance in medicine · 2021
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ye TianUtah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America.
Jason MendesUtah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America.
Apoorva PedgaonkarUtah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America.
Mark IbrahimDivision of Cardiology, University of Utah, Salt Lake City, Utah, United States of America.
Leif JensenUtah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America.
Joyce D SchroederUtah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America.ORCID 0000-0002-7451-4886
Brent WilsonDivision of Cardiology, University of Utah, Salt Lake City, Utah, United States of America.
Edward V R DiBellaUtah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America.ORCID 0000-0001-9196-3731
Ganesh AdluruUtah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States of America.ORCID 0000-0001-9530-1743

Funding

Quantitative MRI for characterizing heart failure with preserved ejection fractionR01HL135328 · NHLBI · UNIVERSITY OF UTAH · PI DIBELLA, EDWARD VR · 2017 to 2020
$2.6M
Improved Estimation of Ischemic Burden with Cardiac MRIR01HL138082 · NHLBI · UNIVERSITY OF UTAH · PI ADLURU, GANESH · 2017 to 2020
$1.5M
Siemens MAGNETOM Prisma 3T MRI scannerS10OD018482 · OD · UNIVERSITY OF UTAH · PI PARKER, DENNIS L · 2015 to 2015
$1.2M
NHLBI NIH HHS R01 HL135328NHLBI NIH HHS R01 HL138082NIH HHS S10 OD018482
6 · The paper itself

Abstract

purposeDynamic contrast enhanced MRI of the heart typically acquires 2-4 short-axis (SA) slices to detect and characterize coronary artery disease. This acquisition scheme is limited by incomplete coverage of the left ventricle. We studied the feasibility of using radial simultaneous multi-slice (SMS) technique to achieve SA, 2-chamber and/or 4-chamber long-axis (2CH LA and/or 4CH LA) coverage with and without electrocardiography (ECG) gating using a motion-robust reconstruction framework.

methods12 subjects were scanned at rest and/or stress, free breathing, with or without ECG gating. Multiple sets of radial SMS k-space were acquired within each cardiac cycle, and each SMS set sampled 3 parallel slices that were either SA, 2CH LA, or 4CH LA slices. The radial data was interpolated onto Cartesian space using an SMS GRAPPA operator gridding method. Self-gating and respiratory states binning of the data were done. The binning information as well as a pixel tracking spatiotemporal constrained reconstruction method were applied to obtain motion-robust image reconstructions. Reconstructions with and without the pixel tracking method were compared for signal-to-noise ratio and contrast-to-noise ratio.

resultsFull coverage of the heart (at least 3 SA and 3 LA slices) during the first pass of contrast at every heartbeat was achieved by using the radial SMS acquisition. The proposed pixel tracking reconstruction improves the average SNR and CNR by 21% and 30% respectively, and reduces temporal blurring for both gated and ungated acquisitions.

conclusionAcquiring simultaneous multi-slice SA, 2CH LA and/or 4CH LA myocardial perfusion images in every heartbeat is feasible in both gated and ungated acquisitions. This can add confidence when detecting and characterizing coronary artery disease by revealing ischemia in different views, and by providing apical coverage that is improved relative to SA slices alone. The proposed pixel tracking framework improves the reconstruction while adding little computational cost.

Indexed as

AgedCardiac-Gated Imaging TechniquesCoronary DiseaseElectrocardiographyFemaleHeartHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingMaleMiddle AgedMyocardial Perfusion Imaging

Identifiers

PMID30742641
PMCPMC6370206

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.