Evidence map›Paper›PMID 30737599›Full record

ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2019

A new technique for low-volume continuous sampling of spent dialysate: a validation study.

Rafael Bueno Orcy, Maria Fernanda Antunes, Jean Pierre Oses, Maristela Böhlke

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Rafael Bueno OrcyDepartment of Physiology, Federal University of Pelotas, Pelotas, Brazil.
Maria Fernanda AntunesPostgraduate Program in Health and Behavior, Catholic University of Pelotas, Rua Gonçalves Chaves, 373, Pelotas, 96015-560, Brazil.
Jean Pierre OsesPostgraduate Program in Health and Behavior, Catholic University of Pelotas, Rua Gonçalves Chaves, 373, Pelotas, 96015-560, Brazil.
Maristela BöhlkePostgraduate Program in Health and Behavior, Catholic University of Pelotas, Rua Gonçalves Chaves, 373, Pelotas, 96015-560, Brazil. mbohlke.sul@gmail.com.ORCID http://orcid.org/0000-0001-9372-3475

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The measure of hemodialysis (HD) adequacy recommended nowadays by most guidelines, Kt/V-urea, presents significant drawbacks. Direct dialysis quantification (DDQ) through total dialysate collection (TDC), considered the gold standard measure of HD adequacy, is cumbersome, which precludes its widespread use in clinical practice. The present study aims to validate a low-volume continuous sampling of spent dialysate (CSSD). Cross-sectional study carried out at a university hospital. Throughout 4-h hemodialysis sessions, urea removal was measured by three DDQ methods: TDC, CSSD, and fractional sampling of dialysate (FSD). The primary outcome was the comparison between the total mass of urea removed measured by TDC and the dialysate sampling techniques. The comparison between urea distribution volume (UDV) estimated by anthropometric method and through DDQ was a secondary outcome. The analysis was done through linear regression and Bland-Altman concordance method. Twenty HD sessions were studied. The mean amount of urea collected in TDC and calculated from the 40-mL sample of CSSD were 33.70 ± 11.70 g and 33.90 ± 11.70 g, respectively [r 0.96, p < 0.0001; bias - 0.2 (95% CI - 1.8 to 1.4); limits of agreement - 6.8 to 6.4]. The anthropometric measure, when compared with DDQ method, underestimated UDV in patients with smaller body size. This new simple, inexpensive, and small volume CSSD technique can provide accurate information about the total amount of solutes removed by hemodialysis.

Indexed as

AdultAgedBody SizeCross-Sectional StudiesDialysis SolutionsFemaleHumansMaleMiddle AgedRenal DialysisUreaDialysis SolutionsUreaAdequacyDirect dialysis quantificationHemodialysisSolute removal

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.