Evidence map›Paper›PMID 30733574›Full record

ArticleScientific reports2019

Implementation of digital optical phase conjugation with embedded calibration and phase rectification.

Zhipeng Yu, Meiyun Xia, Huanhao Li, Tianting Zhong, Fangyuan Zhao, Hao Deng, Zihao Li, Deyu Li, Daifa Wang, Puxiang Lai

Abstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Zhipeng YuDepartment of Biomedical Engineering, Hong Kong Polytechnic University, Hong Kong, Hong Kong.
Meiyun XiaSchool of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China.
Huanhao LiDepartment of Biomedical Engineering, Hong Kong Polytechnic University, Hong Kong, Hong Kong.
Tianting ZhongDepartment of Biomedical Engineering, Hong Kong Polytechnic University, Hong Kong, Hong Kong.
Fangyuan ZhaoSchool of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China.
Hao DengSchool of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China.
Zihao LiDepartment of Biomedical Engineering, Hong Kong Polytechnic University, Hong Kong, Hong Kong.
Deyu LiSchool of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China.
Daifa WangSchool of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China.
Puxiang LaiDepartment of Biomedical Engineering, Hong Kong Polytechnic University, Hong Kong, Hong Kong. puxiang.lai@polyu.edu.hk.ORCID 0000-0003-4811-2012

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Focused and controllable optical delivery beyond the optical diffusion limit in biological tissue has been desired for long yet considered challenging. Digital optical phase conjugation (DOPC) has been proven promising to tackle this challenge. Its broad applications, however, have been hindered by the system's complexity and rigorous requirements, such as the optical beam quality, the pixel match between the wavefront sensor and wavefront modulator, as well as the flatness of the modulator's active region. In this paper, we present a plain yet reliable DOPC setup with an embedded four-phase, non-iterative approach that can rapidly compensate for the wavefront modulator's surface curvature, together with a non-phase-shifting in-line holography method for optical phase conjugation in the absence of an electro-optic modulator (EOM). In experiment, with the proposed setup the peak-to-background ratio (PBR) of optical focusing through a standard ground glass in experiment can be improved from 460 up to 23,000, while the full width at half maximum (FWHM) of the focal spot can be reduced from 50 down to 10 μm. The focusing efficiency, as measured by the value of PBR, reaches nearly 56.5% of the theoretical value. Such a plain yet efficient implementation, if further engineered, may potentially boost DOPC suitable for broader applications.

Identifiers

PMID30733574
PMCPMC6367509

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.