ArticleAJNR. American journal of neuroradiology2019
Comparison of Pipeline Embolization Device Sizing Based on Conventional 2D Measurements and Virtual Simulation Using the Sim&Size Software: An Agreement Study.
Article in AJNR. American journal of neuroradiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- Nomogram for predicting in-stent stenosis after pipeline embolization device treatment in patients with unruptured intracranial aneurysm: a multicenter model development and validation study.Annals of medicine · 2026Article
- Virtual implantation of Derivo Embolization Devices using PreSize Neurovascular software: Accuracy evaluation and size selection comparison study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Software-based simulation for pipeline vantage flow diverter preprocedural assessment: Method and validation study.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Article
- High variability in physician estimations of flow-diverting stent deployment versus PreSize Neurovascular software simulation: a comparison study.Journal of neurointerventional surgery · 2024Article
- Verification of software-based preoperative simulation of flow diverters in clinical cases.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2023Article
- Clinical impact of Sim & SizeInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2023Article
- Predicting flow diverter sizing using the AneuGuideJournal of neurointerventional surgery · 2023Article
- Effects of different stent size selection on pipeline embolization device treatment of intracranial aneurysms.Therapeutic advances in neurological disorders · 2023Article
- "Virtual stent" - clinical evaluation and user experience of on-the-fly stent simulation in treatment of cerebral aneurysms.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2022Article
- Semi-automated cerebral aneurysm segmentation and geometric analysis for WEB sizing utilizing a cloud-based computational platform.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2021Article
- Optimal Woven EndoBridge (WEB) Device Size Selection Using Automated Volumetric Software.Brain sciences · 2021Article
- Deployment of flow diverter devices: prediction of foreshortening and validation of the simulation in 18 clinical cases.Neuroradiology · 2019Article
- A Multicenter Pilot Study on the Clinical Utility of Computational Modeling for Flow-Diverter Treatment Planning.AJNR. American journal of neuroradiology · 2019Article
- Pipeline Sizing Based on Computer Simulation.AJNR. American journal of neuroradiology · 2019Article
Corrections and comments
- Commented on by
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeThe Sim&Size software simulates case-specific intraluminal Pipeline Embolization Device behavior, wall apposition, and device length in real-time on the basis of rotational angiography DICOM data. The purpose of this multicenter study was to evaluate whether preimplantation device simulation with the Sim&Size software results in selection of different device dimensions than manual sizing. MATERIALS AND
methodsIn a multicenter cohort of 74 patients undergoing aneurysm treatment with the Pipeline Embolization Device, we compared apparent optimal device dimensions determined by neurointerventionalists with considerable Pipeline Embolization Device experience based on manual 2D measurements taken from rotational angiography with computed optimal dimensions determined by Sim&Size experts blinded to the neurointerventionalists' decision. Agreement between manually determined and computed optimal dimensions was evaluated with the Cohen κ. The significance of the difference was analyzed with the Wilcoxon signed rank test.
resultsThe agreement index between manual selection and computed optimal dimensions was low (κ for diameter = 0.219; κ for length = 0.149,
conclusionsLow agreement between manually determined and computed optimal device dimensions is not proof, per se, that virtual simulation performs better than manual selection. Nevertheless, it ultimately reflects the potential for optimization of the device-sizing process, and use of the Sim&Size software reduces, in particular, device length. Nevertheless, further evaluation is required to clarify the impact of device-dimension modifications on outcome.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials