Evidence map›Paper›PMID 30731348›Full record

ArticleBiosensors & bioelectronics2019

Rapid, label-free genetic detection of enteropathogens in stool without genetic isolation or amplification.

Song Han, Mehmet C Soylu, Ceyhun E Kirimli, Wei Wu, Bhaswati Sen, Suresh G Joshi, Christopher L Emery, Giang Au, Xiaomin Niu, Richard Hamilton and 3 more

Open access · greenAbstract read
In one paragraph

Article in Biosensors & bioelectronics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 2 institutions in 1 country.

Song HanSchool of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA 19104, USA.
Mehmet C SoyluSchool of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA 19104, USA.
Ceyhun E KirimliSchool of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA 19104, USA.
Wei WuDepartment of Materials Science and Engineering, Drexel University, PA 19104, USA.
Bhaswati SenDepartment of Microbiology and Immunology, Drexel University, Philadelphia, PA 10102, USA.
Suresh G JoshiDepartment of Microbiology and Immunology, Drexel University, Philadelphia, PA 10102, USA.
Christopher L EmeryDepartment of Pathology, Drexel University, Philadelphia, PA 10102, USA.
Giang AuSchool of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA 19104, USA.
Xiaomin NiuSchool of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA 19104, USA.
Richard HamiltonDepartment of Emergency Medicine, Drexel University, Philadelphia, PA 10102, USA.
Kyle KrevolinMicrobiology & SIVM Laboratories, Hahnemann University Hospital, Philadelphia, PA 10102, USA.
Wei-Heng ShihDepartment of Materials Science and Engineering, Drexel University, PA 19104, USA.
Wan Y ShihSchool of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, PA 19104, USA. Electronic address: shihwy@drexel.edu.
Drexel University · USHahnemann University Hospital · US

Funding

Rapid, Accurate, and Low-Cost Stool Clostridium difficile Genetic TestR41AI112224 · NIAID · LENIMA FIELD DIAGNOSTICS, LLC · PI SHIH, WAN Y. · 2014 to 2014
$300k
A Low-Cost Portable Multiplex Serum Molecular Test for HBV and HCV DetectionR41AI120445 · NIAID · LENIMA FIELD DIAGNOSTICS, LLC · PI SHIH, WAN Y. · 2015 to 2015
$300k
NIAID NIH HHS R41 AI112224NIAID NIH HHS R41 AI120445
6 · The paper itself

Abstract

Current genetic detection methods require gene isolation, gene amplification and detection with a fluorescent-tagged probe. They typically require sophisticated equipment and expensive fluorescent probes, rendering them not widely available for rapid acute infection diagnoses at the point of care to ensure timely treatment of the diseases. Here we report a rapid genetic detection method that can detect the bacterial gene directly from patient stools using a piezoelectric plate sensor (PEPS) in conjunction with a continuous flow system with two temperature zones. With stools spiked with sodium dodecyl sulfate (SDS) in situ bacteria lysing and DNA denaturation occurred in the high-temperature zone whereas in situ specific detection of the denatured DNA by the PEPS occurred in the lower-temperature zone. The outcome was a rapid genetic detection method that directly detected bacterial genes from stool in < 40 min without the need of gene isolation, gene amplification, or expensive fluorescent tag but with polymerase chain reaction (PCR) sensitivity. In 40 blinded patient stools, it detected the toxin B gene of Clostridium difficile with 95% sensitivity and 95% specificity. The all-electrical, label-free nature of the detection further supports its potential as a low-cost genetic test that can be used at the point of care.

Indexed as

Biosensing TechniquesBacterial ProteinsBacterial ToxinsClostridioides difficileFecesHumansSodium Dodecyl SulfateBacterial ProteinsBacterial ToxinsSodium Dodecyl SulfatetoxB protein, Clostridium difficileAmplification-freeIn situIsolation-freeLabel-freePiezoelectric plate sensorStool bacteria genetic detection

Identifiers

PMID30731348
PMCPMC6469511
OpenAlexW2912177044

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.