Evidence map›Paper›PMID 30731343›Full record

ArticleBiosensors & bioelectronics2019

Development of a novel micro biosensor for in vivo monitoring of glutamate release in the brain.

Mallikarjunarao Ganesana, Elefterios Trikantzopoulos, Yash Maniar, Scott T Lee, B Jill Venton

Abstract read
In one paragraph

Article in Biosensors & bioelectronics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 38 papers.

0numbers the graph read from it
0cells of the map it votes in
38citing papers in PubMed
7.2field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

38 citing papers in PubMed, 118 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
  13. Review
  14. Review
  15. Review
  16. Review
  17. Review
  18. Review
  19. Nanoelectrochemistry reveals how soluble AβProceedings of the National Academy of Sciences of the United States of America · 2023
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Mallikarjunarao GanesanaDepartment of Chemistry and Neuroscience Graduate Program, University of Virginia, Charlottesville, VA, USA.
Elefterios TrikantzopoulosDepartment of Chemistry and Neuroscience Graduate Program, University of Virginia, Charlottesville, VA, USA.
Yash ManiarDepartment of Chemistry and Neuroscience Graduate Program, University of Virginia, Charlottesville, VA, USA.
Scott T LeeDepartment of Chemistry and Neuroscience Graduate Program, University of Virginia, Charlottesville, VA, USA.
B Jill VentonDepartment of Chemistry and Neuroscience Graduate Program, University of Virginia, Charlottesville, VA, USA. Electronic address: jventon@virginia.edu.
University of Virginia · US

Funding

Mechanism and function of transient adenosine signaling in the brainR01NS076875 · NINDS · UNIVERSITY OF VIRGINIA · PI VENTON, B. JILL · 2012 to 2016
$1.6M
Tunable Carbon Electrodes for in vivo Neurotransmitter DetectionR01EB026497 · NIBIB · UNIVERSITY OF VIRGINIA · PI VENTON, B. JILL · 2018 to 2021
$1.4M
NIBIB NIH HHS R01 EB026497NINDS NIH HHS R01 NS076875
6 · The paper itself

Abstract

L- Glutamate is the main excitatory neurotransmitter in the central nervous system and hyperglutamatergic signaling is implicated in neurological and neurodegenerative diseases. Monitoring glutamate with a glutamate oxidase-based amperometric biosensor offers advantages such as high spatial and high temporal resolution. However, commercially-available glutamate biosensors are expensive and larger in size. Here, we report the development of 50 µm diameter biosensor for real-time monitoring of L-glutamate in vivo. A polymer, poly-o-phenylenediamine (PPD) layer was electropolymerized onto a 50 µm Pt wire to act as a permselective membrane. Then, glutamate oxidase entrapped in a biocompatible chitosan matrix was cast onto the microelectrode surface. Finally, ascorbate oxidase was coated to eliminate interferences from high levels of extracellular ascorbic acid present in brain tissue. L-glutamate measurements were performed amperometrically at an applied potential of 0.6 V vs Ag/AgCl. The biosensor exhibited a linear range from 5 to 150 μM, with a high sensitivity of 0.097 ± 0.001 nA/μM and one-week storage stability. The biosensor also showed a rapid steady state response to L-glutamate within 2 s, with a limit of detection of 0.044 μM. The biosensor was used successfully to detect stimulated glutamate in the subthalamic nucleus in brain slices and in vivo. Thus, this biosensor is appropriate for future neuroscience applications.

Indexed as

Biosensing TechniquesAmino Acid OxidoreductasesAnimalsBrainChitosanEnzymes, ImmobilizedGlutamic AcidPolymersRatsAmino Acid OxidoreductasesChitosanEnzymes, ImmobilizedGlutamic AcidPolymersGlutamateGlutamate biosensorIn vivoStimulated glutamate and amperometry

Identifiers

PMID30731343
PMCPMC6449154
OpenAlexW2911738484

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.