Evidence map›Paper›PMID 30727794›Full record

ArticleThe Journal of international medical research2019

Application of second-generation Shikani optical stylet in critically ill patients undergoing cerebral aneurysm embolization.

Xicheng Liu, Yaoxian Zhang, Zhanli Liu, Qiuli Zhang, Wenyan Wu, Zihao Zheng, Zhongjun Zhang

Open access · goldAbstract read
In one paragraph

Article in The Journal of international medical research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Review
  3. A forceps-assisted fiberoptic bronchoscopic intubation.Brazilian journal of anesthesiology (Elsevier)
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Xicheng LiuDepartment of Anesthesiology, The Second Clinical Medical College of Jinan University, Shenzhen People's Hospital, Shenzhen, China.
Yaoxian ZhangDepartment of Anesthesiology, The Second Clinical Medical College of Jinan University, Shenzhen People's Hospital, Shenzhen, China.
Zhanli LiuDepartment of Anesthesiology, The Second Clinical Medical College of Jinan University, Shenzhen People's Hospital, Shenzhen, China.
Qiuli ZhangDepartment of Anesthesiology, The Second Clinical Medical College of Jinan University, Shenzhen People's Hospital, Shenzhen, China.
Wenyan WuDepartment of Anesthesiology, The Second Clinical Medical College of Jinan University, Shenzhen People's Hospital, Shenzhen, China.
Zihao ZhengDepartment of Anesthesiology, The Second Clinical Medical College of Jinan University, Shenzhen People's Hospital, Shenzhen, China.
Zhongjun ZhangDepartment of Anesthesiology, The Second Clinical Medical College of Jinan University, Shenzhen People's Hospital, Shenzhen, China.ORCID https://orcid.org/0000-0001-8445-6512
Jinan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study was performed to compare the clinical value of the second-generation Shikani optical stylet with that of the Macintosh laryngoscope for tracheal intubation of patients undergoing cerebral aneurysm embolization.

methodsThirty-six patients who underwent cerebral aneurysm embolization were included. The intubation time, intubation success rate, blood oxygen saturation, heart rate, systolic blood pressure (SBP), and diastolic blood pressure (DBP) were measured. Adverse reactions during tracheal intubation and the local tissue injury rate were recorded. Comparisons between the groups were performed with one-way analysis of variance.

resultsThe heart rate, SBP, and DBP upon tracheal intubation and at 1 and 3 minutes were significantly higher in the Macintosh laryngoscope group than in the Shikani optical stylet group. The time to completion of tracheal intubation was significantly shorter and the tissue injury rate was significantly lower in the Shikani optimal stylet group than in the Macintosh laryngoscope group.

conclusionsThe second-generation Shikani optical stylet is a simple, safe, and reliable tool for tracheal intubation in critically ill patients undergoing cerebral aneurysm embolization.

Indexed as

Embolization, TherapeuticAgedBlood PressureCritical IllnessFemaleFollow-Up StudiesHeart RateHumansIntracranial AneurysmIntubation, IntratrachealLaryngoscopyMaleMiddle AgedPrognosiscerebral aneurysm embolizationcritically ill patientsMacintosh laryngoscopeOptical stylettissue injury ratetracheal intubation

Identifiers

PMID30727794
PMCPMC6460621
OpenAlexW2914227590

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.