Evidence map›Paper›PMID 30723684›Full record

ArticleJournal of orthopaedic translation2019

Comparison of knee joint orientation in clinically versus biomechanically aligned computed tomography coordinate system.

Thomas P Scherer, Sebastian Hoechel, Magdalena Müller-Gerbl, Andrej M Nowakowski

Abstract read
In one paragraph

Article in Journal of orthopaedic translation, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Thomas P SchererDepartment of Biomedicine, Musculoskeletal Research, University of Basel, Pestalozzistrasse 20, CH-4056 Basel, Switzerland.
Sebastian HoechelDepartment of Biomedicine, Musculoskeletal Research, University of Basel, Pestalozzistrasse 20, CH-4056 Basel, Switzerland.
Magdalena Müller-GerblDepartment of Biomedicine, Musculoskeletal Research, University of Basel, Pestalozzistrasse 20, CH-4056 Basel, Switzerland.
Andrej M NowakowskiDepartment of Biomedicine, Musculoskeletal Research, University of Basel, Pestalozzistrasse 20, CH-4056 Basel, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPreoperative planning of total knee arthroplasty is usually performed using knee-centred computed tomography (CT) data sets. The disadvantage of these data sets is having no account of the biomechanical axis of the lower extremity, known as Mikulicz line. It aligns the femoral head to the middle of the talocrural joint. For optimal prosthesis arrangement, the knee CT data set must therefore be brought in congruency with this line of loading to achieve the best results and eliminate rotational malalignments.This study aims to establish a relation between the knee-centred clinical coordinate system (CCS) and a biomechanical coordinate system (BCS) based on the Mikulicz line.

methodsCT data sets of 45 lower extremities were evaluated. Using VG Studio Max, a visualisation and measurement software program; each CT data set was aligned according to the CCS and BCS. After superimposing both the aligned data sets, the deviations of both coordinate systems in all three planes were measured with the centre of the knee defined as the origin.

resultsFor the coronal plane, the CCS was demonstrated to be 2.54° in adduction compared to the BCS [standard deviation (SD) = 1.8°]. In sagittal view, the CCS was demonstrated to be 0.3° retroversed (SD = 3.27°). Finally, the deviation in the axial plane showed an outward rotation of 3.39° (SD = 1.99°). The alignment as well as the measurements demonstrated high intraobserver and interobserver reproducibility.

conclusionBoth coordinate systems can be established in knee-centred CT data sets in a reproducible manner. Clearly, the CCS differs significantly from the BCS describing the biomechanical axis, but mathematical-based adaptations and corrections can be performed. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The findings of this study allow a mathematical conversion of a knee CT to the biomechanical axis of the leg.

Indexed as

AlignmentComputed tomographyCoordinate systemMikulicz lineTotal knee arthroplasty

Identifiers

PMID30723684
PMCPMC6350020

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.