Trial reportJAMA internal medicine2019
Self-compression Technique vs Standard Compression in Mammography: A Randomized Clinical Trial.
Trial report in JAMA internal medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02866591 (Interest of Self-compression Technique on Tolerance of Mammography), which is not on this map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Interest of Self-compression Technique on Tolerance of Mammography
Who cites it
3 citing papers in PubMed.
- Patient Preference and Adherence in Mammography Screening: A Narrative Review.Patient preference and adherence · 2026Review
- The Breast Impact Monitoring System: A Portable and Wearable Platform to Support Injury Prevention in Female Athletes.Sensors (Basel, Switzerland) · 2025Article
- Acceptability of Automated Robotic Clinical Breast Examination: Survey Study.Journal of participatory medicine · 2023Article
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: Many women dread undergoing mammography, and some may not attend or reattend breast cancer screening because of the discomfort or pain induced by breast compression. Objective: To evaluate the noninferiority of the self-compression mammography technique for reducing breast thickness compared with standard compression. Design, Setting, and Participants: This prospective, parallel-group, noninferiority randomized clinical trial was conducted from May 7, 2013, to October 26, 2015, at 6 cancer care centers in France. Participants were women aged 50 to 75 years, without a history of recent breast surgical procedure or treatment, and who could perform self-compression. Analyses were performed on intention-to-treat basis from January 27, 2017, to March 30, 2018. Interventions: Patients were randomized 1:1 to the self-compression group or the standard compression group. Main Outcomes and Measures: Primary end point was breast thickness expressed as the mean of 4 views: right and left craniocaudal and right and left mediolateral oblique. The predefined noninferiority margin was a difference of 3 mm, with a 1-sided 95% CI. Secondary end points included compression force, image quality, requirement for additional views, pain, and patient satisfaction and radiographer assessment questionnaires. Results: Among the 549 women randomized, 548 (97.3%) completed the trial. Of these, 275 (48.8%) (mean [SD] age, 61.35 [6.34] years) were randomized to the self-compression arm and 273 (48.5%) (mean [SD] age, 60.84 [6.41] years) to the standard compression arm. The difference in the mean thickness between the 2 arms was lower than the noninferiority margin, with an upper 1-sided 95% CI less than 3 mm (-0.17; 95% CI,-∞ to 1.89 mm; P < .05). Compression force was higher in the self-compression group compared with the standard compression arm for the 4 mammographic views. Pain was statistically significantly lower in the self-compression group (n = 274) compared with the standard compression group (n = 269) (median [interquartile range (IQR)] score, 2 [1-5] vs 3 [1-5]; P = .009). No difference was reported in the image quality scores of the 2 groups or in the number of additional views performed (median [IQR] extra views, 2 [2-2] vs 2 [2-3] extra views; P = .64), whatever the indication, including insufficient image quality (29 [16.8%] vs 27 [15.0%] insufficient quality views; P = .65). No adverse effects or pain were reported by the participants after the self-compression mammography. Conclusions and Relevance: Self-compression does not appear to be inferior to standard compression mammography in achieving minimal breast thickness without increasing pain or compromising image quality; this technique may be an effective option for women who want to be involved in their breast examination. Trial Registration: ClinicalTrials.gov identifier: NCT02866591.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.