ArticleActa bio-medica : Atenei Parmensis2019
Can UKA after KineSpring system failure be a viable option? A case report.
Article in Acta bio-medica : Atenei Parmensis, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- [Knee joint distraction : A short narrative literature review].Orthopadie (Heidelberg, Germany) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and aim of the workThe KineSpring System is an alternative treatment offered in selected symptomatic patients suffering from mild to moderate medial knee osteoarthritis (OA). This device reduces medial compartment loads in the OA knee without compromising the integrity of the lateral or patellofemoral knee compartments, maintaining the normal knee anatomy. Currently, papers about KineSpring System installation show promising results. The current authors describe a case of unicompartmental knee arthroplasty (UKA) employed to treat medial knee OA after Kinespring system failure.
methodsA 64-year old male patient presented to our hospital after failure of a Kinespring system implantation into his left knee at an external hospital, where the outcomes obtained were not satisfactory. The surgical options discussed with the patient were the TKA or medial UKA. A medial UKA was preferred by the patient.
resultsOne year from UKA, the patient complained of frequent joint effusions and weight bearing pain despite a good ROM without radiographic signs of implant loosening. Therefore, after two years we replaced UKA with total knee arthroplasty (TKA).
conclusionsFurther experience is needed to provide reliable clinical data about the results of the UKA after KineSpring System discharge.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.