Evidence map›Paper›PMID 30711626›Full record

ArticleGastroenterology2019

Development and Validation of a Mucosal Impedance Contour Analysis System to Distinguish Esophageal Disorders.

Dhyanesh A Patel, Tina Higginbotham, James C Slaughter, Muhammad Aslam, Elif Yuksel, David Katzka, C Prakash Gyawali, Melina Mashi, John Pandolfino, Michael F Vaezi

2 registry-linked trialsOpen access · bronzeAbstract readMulticenter StudyValidation Study
In one paragraph

Article in Gastroenterology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 47 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
47citing papers in PubMed, 2 pooled it
12.1field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03103789 enrolling by invitationnot on this map

Assessment of Esophageal Epithelium Integrity With Use of a Novel Mucosal Impedance Device

TypeobservationalSponsorVanderbilt University Medical CenterRan2014 to 2026Enrolled75ConditionsGastro Esophageal RefluxArmssingle catheter mucosal impedance testing, balloon assembly mucosal impedance testing
NCT07227506 recruitingnot on this mapstarted 2025, after this paper: background citation

Diagnostic Utility of Mucosal Impedance Device in Patients With GERD and Chronic Esophageal Disorders:

Typeobservational_patient_registrySponsorMedical College of WisconsinRan2025 to 2028Enrolled50ConditionsGerd, Eosinophilic EsophagitisArmsMuVI Esophageal mucosal impedance testing
3 · Its place in the literature

Who cites it

47 citing papers in PubMed, 2 syntheses or guidelines pooled it, 92 citations in OpenAlex.

  1. Guideline
  2. Pooled it
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Reflux Testing: Wireless pH, Impedance-pH, and Mucosal Impedance.Gastrointestinal endoscopy clinics of North America · 2025
    Review
  9. Review
  10. Article
  11. Review
  12. Review
  13. The Saudi Gastroenterology Association consensus on the clinical care pathway for the diagnosis and treatment of GERD.Saudi journal of gastroenterology : official journal of the Saudi Gastroenterology Association · 2024
    Article
  14. Novel Technique to Diagnose Gastroesophageal Reflux Disease.The Korean journal of helicobacter and upper gastrointestinal research · 2024
    Review
  15. Mucosal impedance as a diagnostic tool for gastroesophageal reflux disease: an update for clinicians.Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus · 2024
    Review
  16. Article
  17. Article
  18. Article
  19. Barrier Dysfunction in Eosinophilic Esophagitis.Current gastroenterology reports · 2023
    Review
  20. Esophageal Epithelium and Lamina Propria Are Unevenly Involved in Eosinophilic Esophagitis.Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 5 institutions in 2 countries.

Dhyanesh A PatelDivision of Gastroenterology, Hepatology and Nutrition, Vanderbilt University Medical Center, Nashville, Tennessee.
Tina HigginbothamDivision of Gastroenterology, Hepatology and Nutrition, Vanderbilt University Medical Center, Nashville, Tennessee.
James C SlaughterDepartment of Biostatistics, Vanderbilt University Medical Center, Nashville, Tennessee.
Muhammad AslamDivision of Gastroenterology, Hepatology and Nutrition, Vanderbilt University Medical Center, Nashville, Tennessee.
Elif YukselDepartment of Gastroenterology, Izmir Ataturk Teaching and Research Hospital, Katip Celebi University, Izmir, Turkey.
David KatzkaDivision of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota.
C Prakash GyawaliDivision of Gastroenterology, Washington University Medical Center, St Louis, Missouri.
Melina MashiDivision of Gastroenterology and Hepatology, Northwestern University Feinberg School of Medicine, Chicago, Illinois.
John PandolfinoDivision of Gastroenterology and Hepatology, Northwestern University Feinberg School of Medicine, Chicago, Illinois.
Michael F VaeziDivision of Gastroenterology, Hepatology and Nutrition, Vanderbilt University Medical Center, Nashville, Tennessee. Electronic address: Michael.vaezi@vumc.org.
Vanderbilt University Medical Center · USNorthwestern University · USIzmir Kâtip Çelebi University · TRMayo Clinic · USWashington University Medical Center · US

Funding

Targeting Hypervigilance and Autonomic Arousal: the Psycho-physiologic Model of GERDR01DK092217 · NIDDK · NORTHWESTERN UNIVERSITY AT CHICAGO · PI JOHN E PANDOLFINO · 2012 to 2026
$5.0M
NIDDK NIH HHS R01 DK092217
6 · The paper itself

Abstract

BACKGROUND &

aimsDiagnostic testing for chronic esophageal disorders relies on histopathology analysis of biopsies or uncomfortable transnasal catheters or wireless pH monitoring, which capture abnormal intraluminal refluxate. We therefore developed a balloon mucosal impedance (MI) catheter system that instantly detects changes in esophageal mucosal integrity during endoscopy over a long segment of the esophagus. We performed a prospective study to evaluate the ability of a balloon-incorporated MI catheter to detect and evaluate esophageal disorders, including gastroesophageal reflux disease (GERD) and eosinophilic esophagitis (EoE).

methodsWe performed a prospective study of 69 patients undergoing esophagogastroduodenoscopy with or without wireless pH monitoring. Patients were classified as having GERD (erosive esophagitis or abnormal pH; n = 24), EoE (confirmed with pathology analysis of tissues from both distal and proximal esophagus; n = 21), or non-GERD (normal results from esophagogastroduodenoscopy and pH tests; n = 24). Receiver operating characteristic curves and area under the operating characteristic curve (AUC) were used to compare the accuracy of balloon MI in diagnosis. Probabilities of assignment to each group (GERD, non-GERD, or EoE) were estimated using multinomial logistic regression. Association between MI patterns and diagnoses were validated using data from patients seen at 3 separate institutions.

resultsMI pattern along the esophageal axis differed significantly (P < .01) among patients with GERD, EoE, and non-GERD. Patients with non-GERD had higher MI values along all measured segments. The MI pattern for GERD was easily distinguished from that of EoE: in patients with GERD, MI values were low in the distal esophagus and normalized along the proximal esophagus, whereas in patients with EoE, measurements were low in all segments of the esophagus. Intercept and rate of rise of MI value (slope) as distance increased from the squamocolumnar junction identified patients with GERD with an AUC = 0.67, patients with EoE with an AUC = 0.84, and patients with non-GERD with an AUC = 0.83 in the development cohort. One patient had an adverse event (reported mild chest pain after the procedure) and was discharged from the hospital without further events.

conclusionsWe developed a balloon MI catheter system that instantly detects changes in esophageal mucosal integrity during endoscopy and found it to be safe and able to identify patients with GERD, EoE, or non-GERD. We validated our findings in a separate cohort for patients. ClinicalTrials.gov ID NCT03103789.

Indexed as

CathetersElectric ImpedanceAdultAgedArea Under CurveDiagnosis, DifferentialEndoscopy, GastrointestinalEosinophilic EsophagitisEquipment DesignEsophageal MucosaEsophageal pH MonitoringFemaleGastroesophageal RefluxHumansMaleMiddle AgedDiagnosticImpedance ContourPredictive ModelPrognostic

Identifiers

PMID30711626
PMCPMC6990978
OpenAlexW2914593478

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.