ArticleGastroenterology2019
Development and Validation of a Mucosal Impedance Contour Analysis System to Distinguish Esophageal Disorders.
Article in Gastroenterology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 47 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Assessment of Esophageal Epithelium Integrity With Use of a Novel Mucosal Impedance Device
Diagnostic Utility of Mucosal Impedance Device in Patients With GERD and Chronic Esophageal Disorders:
Who cites it
47 citing papers in PubMed, 2 syntheses or guidelines pooled it, 92 citations in OpenAlex.
- Eosinophilic esophagitis in children and adolescents: a clinical practice guideline.Italian journal of pediatrics · 2025Guideline
- Endoluminal Procedures and Devices for Esophageal Tract Investigation: A Critical Review.Sensors (Basel, Switzerland) · 2023Pooled it
- Proximal Esophageal Impedance Contour Predicts Increased Reflux Burden in Patients With Laryngopharyngeal Symptoms.Clinical and translational gastroenterology · 2026Article
- Laryngopharyngeal reflux current developments and therapeutic strategies.BMC gastroenterology · 2026Review
- Gastrointestinal endoscopy for physiological assessment in functional gastrointestinal disorders: a perspective.Frontiers in medicine · 2026Article
- Vietnam Association of Gastroenterology (VNAGE) guideline on the management of gastroesophageal reflux disease.Frontiers in medicine · 2026Review
- Emerging innovation, artificial intelligence, and digital technology in esophagology.Annals of the New York Academy of Sciences · 2025Review
- Reflux Testing: Wireless pH, Impedance-pH, and Mucosal Impedance.Gastrointestinal endoscopy clinics of North America · 2025Review
- Eosinophilic oesophagitis in adults: from symptoms to therapeutic options.Internal and emergency medicine · 2025Review
- Study design of the phase IV, randomized, placebo-controlled REMOdeling with Dupilumab in Eosinophilic esophagitis Long-term (REMODEL) trial.Therapeutic advances in gastroenterology · 2025Article
- Hyaluronic acid and chondroitin sulfate-based medical devices: formulations, esophageal mucosal protection, and their place in the management of GERD.Therapeutic advances in gastroenterology · 2025Review
- Diagnosis and Management of Gastroesophageal Reflux Disease: Current Insights.Clinical and experimental gastroenterology · 2025Review
- The Saudi Gastroenterology Association consensus on the clinical care pathway for the diagnosis and treatment of GERD.Saudi journal of gastroenterology : official journal of the Saudi Gastroenterology Association · 2024Article
- Novel Technique to Diagnose Gastroesophageal Reflux Disease.The Korean journal of helicobacter and upper gastrointestinal research · 2024Review
- Mucosal impedance as a diagnostic tool for gastroesophageal reflux disease: an update for clinicians.Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus · 2024Review
- Esophageal Mucosal Impedance Assessment for the Diagnosis of Gastroesophageal Reflux Disease.Journal of neurogastroenterology and motility · 2024Article
- The utility of balloon-based and standard impedance technology to diagnose esophageal mucosal diseases in children.Neurogastroenterology and motility · 2024Article
- Latin American consensus on diagnosis of gastroesophageal reflux disease.Neurogastroenterology and motility · 2024Article
- Barrier Dysfunction in Eosinophilic Esophagitis.Current gastroenterology reports · 2023Review
- Esophageal Epithelium and Lamina Propria Are Unevenly Involved in Eosinophilic Esophagitis.Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 5 institutions in 2 countries.
Funding
Abstract
BACKGROUND &
aimsDiagnostic testing for chronic esophageal disorders relies on histopathology analysis of biopsies or uncomfortable transnasal catheters or wireless pH monitoring, which capture abnormal intraluminal refluxate. We therefore developed a balloon mucosal impedance (MI) catheter system that instantly detects changes in esophageal mucosal integrity during endoscopy over a long segment of the esophagus. We performed a prospective study to evaluate the ability of a balloon-incorporated MI catheter to detect and evaluate esophageal disorders, including gastroesophageal reflux disease (GERD) and eosinophilic esophagitis (EoE).
methodsWe performed a prospective study of 69 patients undergoing esophagogastroduodenoscopy with or without wireless pH monitoring. Patients were classified as having GERD (erosive esophagitis or abnormal pH; n = 24), EoE (confirmed with pathology analysis of tissues from both distal and proximal esophagus; n = 21), or non-GERD (normal results from esophagogastroduodenoscopy and pH tests; n = 24). Receiver operating characteristic curves and area under the operating characteristic curve (AUC) were used to compare the accuracy of balloon MI in diagnosis. Probabilities of assignment to each group (GERD, non-GERD, or EoE) were estimated using multinomial logistic regression. Association between MI patterns and diagnoses were validated using data from patients seen at 3 separate institutions.
resultsMI pattern along the esophageal axis differed significantly (P < .01) among patients with GERD, EoE, and non-GERD. Patients with non-GERD had higher MI values along all measured segments. The MI pattern for GERD was easily distinguished from that of EoE: in patients with GERD, MI values were low in the distal esophagus and normalized along the proximal esophagus, whereas in patients with EoE, measurements were low in all segments of the esophagus. Intercept and rate of rise of MI value (slope) as distance increased from the squamocolumnar junction identified patients with GERD with an AUC = 0.67, patients with EoE with an AUC = 0.84, and patients with non-GERD with an AUC = 0.83 in the development cohort. One patient had an adverse event (reported mild chest pain after the procedure) and was discharged from the hospital without further events.
conclusionsWe developed a balloon MI catheter system that instantly detects changes in esophageal mucosal integrity during endoscopy and found it to be safe and able to identify patients with GERD, EoE, or non-GERD. We validated our findings in a separate cohort for patients. ClinicalTrials.gov ID NCT03103789.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.