Evidence map›Paper›PMID 30707737›Full record

ArticlePloS one2019

Validation of an equation for energy expenditure that does not require the respiratory quotient.

Karl J Kaiyala, Brent E Wisse, John R B Lighton

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.6field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 18 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Karl J KaiyalaDepartment of Oral Health Sciences, School of Dentistry, University of Washington, Seattle, Washington United States of America.ORCID 0000-0002-1604-4505
Brent E WisseDepartment of Medicine, University of Washington, Seattle Washington, United States of America.
John R B LightonSable Systems International Inc., North Las Vegas, Nevada, United States of America.
University of Washington · US

Funding

Coordinating and Bioinformatics Unit for the MMPC/DiaCompU24DK076169 · NIDDK · AUGUSTA UNIVERSITY · PI MCINDOE, RICHARD A. · 2006 to 2018
$42.4M
NIDDK NIH HHS U24 DK076169
6 · The paper itself

Abstract

backgroundEnergy expenditure (EE) calculated from respirometric indirect calorimetry is most accurate when based on oxygen consumption (VO2), carbon dioxide production (VCO2) and estimated protein metabolism (PM). EE has a substantial dependence of ~7% on the respiratory quotient (RQ, VCO2/VO2) and a lesser dependence on PM, yet many studies have instead estimated EE from VO2 only while PM has often been ignored, thus reducing accuracy. In 1949 Weir proposed a method to accurately calculate EE without using RQ, which also adjusts for estimated PM based on dietary composition. This RQ- method utilizes the calorimeter airflow rate (FR), the change in fractional O2 concentration (ΔFO2) and the dietary protein fraction. The RQ- method has not previously been empirically validated against the standard RQ+ method using both VO2 and RQ. Our aim was to do that.

methodsVO2 and VCO2 were measured repeatedly in 8 mice fed a high protein diet (HPD) during exposure to different temperatures (n = 168 measurements of 24h gas exchange). The HPD-adjusted RQ+ equation was: EE [kcal/time] = VO2 [L/time]×(3.853+1.081RQ) while the corresponding RQ- equation was: EE = 4.934×FR×ΔFO2. Agreement was analyzed using the ratios of the RQ- to RQ+ methods along with regression and Bland-Altman agreement analyses. We also evaluated the standard equation using the dietary food quotient (FQ) of 0.91 as a proxy for RQ (FQ+ method).

resultsRatio analysis revealed that the mean error of the RQ- method was only 0.11 ± 0.042% while the maximum error was only 0.21%. Error using the FQ+ method was 4 -and 10-fold greater, respectively. Bland-Altman analysis demonstrated that the RQ- method very slightly overestimates EE as RQ decreases. Theoretically, this error can be eliminated completely by imposing an incurrent fractional oxygen concentration at a value only slightly greater than the atmospheric level.

conclusionsThe Weir 'RQ-free' method for calculating EE is a highly valid alternative to the 'gold standard' method that requires RQ. The RQ- approach permits reduced cost and complexity in studies focused on EE and provides a way to rescue EE measurement in studies compromised by faulty CO2 measurements. Practitioners of respirometry should consider adjusting EE calculations for estimated protein metabolism based on dietary composition.

Indexed as

Energy MetabolismAlgorithmsAnimalsCarbon DioxideDiet, High-ProteinMaleMiceMice, Inbred C57BLOxygen ConsumptionProteinsTemperatureCarbon DioxideProteins

Identifiers

PMID30707737
PMCPMC6358081
OpenAlexW2912371553

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.