Evidence map›Paper›PMID 30701162›Full record

ArticleQuantitative imaging in medicine and surgery2018

Acoustic field simulation method for arbitrarily shaped transducer with dynamically refined sub-elements.

Jiaying Xiao, Mengdi Xiao, Bo Wang, Zhongchao Huang, Kuan Peng

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jiaying XiaoDepartment of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha 410083, China.
Mengdi XiaoDepartment of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha 410083, China.
Bo WangCollege of Biology, Hunan University, Changsha 410082, China.
Zhongchao HuangDepartment of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha 410083, China.
Kuan PengDepartment of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha 410083, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSimulation of the emitted acoustic field is crucial to the design of ultrasound transducers. The method based on the spatial impulse response (SIR) and aperture discretization provides a powerful tool to study the acoustic field emitted by a transducer with complex aperture geometry and sophisticated apodization/excitation pattern.

methodsIn this work, a new method based on the dynamically refined sub-elements (SE) is employed to discrete the aperture and generate the SIR. Then, these SIRs are convoluted with the excitation pulse to get the acoustic pressure (AP) signal. When calculating the SIR with this method, the slowly changed time flight from a SE to a field point (FP) is approximated with a step function, and the fast changed length of intersection between a SE and a spherical wave centered at a FP is accurately estimated with the areas of the sub-parts (SP) which are given by the dynamically refined SE.

resultsSimulations of the acoustic field created by a focusing transducer array and a hollow structured point focusing transducer indicate that the proposed new method can give similar data accuracy with a sampling frequency 16 times lower than the conventional time tracing SE (TTSE) based method. The computational cost is also reduced by nearly one order of magnitude.

conclusionsA new method is proposed to simulate the acoustic field emitted by transducers with complex geometrical structure and sophisticated apodization/excitation patterns. The required sampling frequency with the new algorithm is greatly reduced compared to that of the conventional TTSE-based method; thus, the efficiency of the acoustic field calculation is improved significantly.

Indexed as

Acoustic fieldspatial impulse response (SIR)transducer

Identifiers

PMID30701162
PMCPMC6328381

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.