ArticleJournal of clinical microbiology2019
Performance of a Novel Low-Cost, Instrument-Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study.
Article in Journal of clinical microbiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it, 49 citations in OpenAlex.
- Viral load monitoring for people living with HIV in the era of test and treat: progress made and challenges ahead - a systematic review.BMC public health · 2022Pooled it
- Switch to second-line versus continued first-line antiretroviral therapy for patients with low-level HIV-1 viremia: An open-label randomized controlled trial in Lesotho.PLoS medicine · 2020Trial
- Dried Blood Spots and Plasma Separation Cards can Broaden Access to Molecular Testing for HBV, HCV and HIV.Reviews in medical virology · 2025Review
- Dried Blood Spots and Plasma Separation Cards can Broaden Access to Molecular Testing for HBV, HCV and HIV.Reviews in medical virology · 2025Review
- Clinical evaluation of patterned dried plasma spot cards to support quantification of HIV viral load and reflexive genotyping.Proceedings of the National Academy of Sciences of the United States of America · 2025Article
- Use of laboratory-developed assays in global HIV-1 treatment-monitoring and research.Scientific reports · 2023Review
- Left behind on the path to 90-90-90: understanding and responding to HIV among displaced people.Journal of the International AIDS Society · 2022Article
- Point-of-Care Diagnostics for Diagnosis of Active Syphilis Infection: Needs, Challenges and the Way Forward.International journal of environmental research and public health · 2022Article
- A point-of-care lateral flow assay for neutralising antibodies against SARS-CoV-2.EBioMedicine · 2021Article
- Accurate HIV viral load measurement in primary health care settings using the cobas® plasma separation card.PloS one · 2020Article
- Field Suitability and Diagnostic Accuracy of the Biocentric Open Real-Time PCR Platform for Dried Blood Spot-Based HIV Viral Load Quantification in Eswatini.Journal of acquired immune deficiency syndromes (1999) · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
16 authors at 5 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
HIV viral load (VL) testing is the recommended method for monitoring the response of people living with HIV and receiving antiretroviral therapy (ART). The availability of standard plasma VL testing in low- and middle-income countries (LMICs), and access to this testing, are limited by the need to use fresh plasma. Good specimen collection methods for HIV VL testing that are applicable to resource-constrained settings are needed. We assessed the diagnostic performance of the filtered dried plasma spot (FDPS), created using the newly developed, instrument-free VLPlasma device, in identifying treatment failure at a VL threshold of 1,000 copies/ml in fresh plasma. Performance was compared with that of the conventional dried blood spot (DBS). Venous blood samples from 201 people living with HIV and attending an infectious disease clinic in Malaysia were collected, and HIV VL was quantified using fresh plasma (the reference standard), FDPS, and DBS specimens. VL testing was done using the Roche Cobas AmpliPrep/Cobas TaqMan v2.0 assay. At a threshold of 1,000 copies/ml, the diagnostic performance of the FDPS was superior (sensitivity, 100% [95% confidence interval {CI}, 89.1 to 100%]; specificity, 100% [95% CI, 97.8 to 100%]) to that of the DBS (sensitivity, 100% [95% CI, 89.4 to 100%]; specificity, 36.8% [95% CI, 29.4 to 44.7%]) (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials