Evidence map›Paper›PMID 30699210›Full record

ArticlePloS one2019

Numerical and in-vitro experimental assessment of the performance of a novel designed expanded-polytetrafluoroethylene stentless bi-leaflet valve for aortic valve replacement.

Guangyu Zhu, Munirah Binte Ismail, Masakazu Nakao, Qi Yuan, Joon Hock Yeo

Open access · goldAbstract readValidation Study
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.4field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Frontiers in bioengineering and biotechnology · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Guangyu ZhuSchool of Energy and Power Engineering, Xi'an Jiaotong University, Xian, Shaanxi, China.ORCID 0000-0002-3469-3779
Munirah Binte IsmailSchool of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore.
Masakazu NakaoCardiothoracic Surgery, KK Women's and Children's Hospital, Singapore, Singapore.
Qi YuanSchool of Energy and Power Engineering, Xi'an Jiaotong University, Xian, Shaanxi, China.
Joon Hock YeoSchool of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore.
Nanyang Technological University · SGKK Women's and Children's Hospital · SGXi'an Jiaotong University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The expanded polytetrafluoroethylene (ePTFE) heart valve can serve as a viable option for prosthetic aortic valve. In this study, an ePTFE bi-leaflet valve design for aortic valve replacement (AVR) is presented, and the performance of the proposed valve was assessed numerically and experimentally. The valve was designed using CAE software. The dynamic behavior of the newly designed bi-leaflet valve under time-varying physiological pressure loading was first investigated by using commercial finite element code. Then, in-vitro tests were performed to validate the simulation and to assess the hemodynamic performance of the proposed design. A tri-leaflet ePTFE valve was tested in-vitro under the same conditions as a reference. The maximum leaflet coaptation area of the bi-leaflet valve during diastole was 216.3 mm2. When fully closed, no leakage gap was observed and the free edges of the molded valve formed S-shaped lines. The maximum Von Mises stress during a full cardiac cycle was 4.20 MPa. The dynamic performance of the bi-leaflet valve was validated by the in-vitro test under physiological aortic pressure pulse. The effective orifice area (EOA), mean pressure gradient, regurgitant volume, leakage volume and energy loss of the proposed valve were 3.14 cm2, 8.74 mmHg, 5.93 ml/beat, 1.55 ml/beat and 98.99 mJ, respectively. This study reports a novel bi-leaflet valve design for AVR. The performance of the proposed valve was numerically and experimentally assessed. Compared with the reference valve, the proposed design exhibited better structural and hemodynamic performances, which improved valve competency. Moreover, the performance of the bi-leaflet design is comparable to commercialized valves available on the market. The results of the present study provide a viable option for the future clinical applications.

Indexed as

Aortic ValveHeart Valve ProsthesisProsthesis DesignArterial PressureComputer-Aided DesignComputer SimulationCoronary CirculationFinite Element AnalysisHemodynamicsHumansImaging, Three-DimensionalIn Vitro TechniquesModels, CardiovascularPolytetrafluoroethyleneStress, MechanicalPolytetrafluoroethylene

Identifiers

PMID30699210
PMCPMC6353165
OpenAlexW2913531462

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.