Evidence map›Paper›PMID 30696987›Full record

ArticlePediatric research2019

The point-of-care Bilistick method has very short turn-around-time and high accuracy at lower cutoff levels to predict laboratory-measured TSB.

Nem-Yun Boo, Yun-Fah Chang, Ying-Xin Leong, Zhen-Yu Tok, Lai-Cheng Hooi, Seok-Chiong Chee, Zuraidah Abdul Latif

Abstract readMulticenter Study
PubMed Publisher
In one paragraph

Article in Pediatric research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. [Global disease burden of neonatal jaundice from 1990 to 2019].Zhongguo dang dai er ke za zhi = Chinese journal of contemporary pediatrics · 2023
    Article
  6. Article
  7. Observational
  8. Review
  9. Article
  10. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Nem-Yun BooDepartment of Population Medicine, Faculty of Medicine and Health Sciences, University Tunku Abdul Rahman, Selangor, Malaysia. boony@utar.edu.my.ORCID http://orcid.org/0000-0002-3535-4795
Yun-Fah ChangDepartment of Mathematical and Actuarial Sciences, Faculty of Engineering and Science, University Tunku Abdul Rahman, Selangor, Malaysia.
Ying-Xin LeongDepartment of Population Medicine, Faculty of Medicine and Health Sciences, University Tunku Abdul Rahman, Selangor, Malaysia.
Zhen-Yu TokDepartment of Population Medicine, Faculty of Medicine and Health Sciences, University Tunku Abdul Rahman, Selangor, Malaysia.
Lai-Cheng HooiDepartment of Population Medicine, Faculty of Medicine and Health Sciences, University Tunku Abdul Rahman, Selangor, Malaysia.
Seok-Chiong CheeDepartment of Paediatrics, Hospital Selayang, Selangor, Malaysia.
Zuraidah Abdul LatifDepartment of Paediatrics, Hospital Ampang, Selangor, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aimed to determine the accuracy of a point-of-care Bilistick method for measuring total serum bilirubin (TSB) and its turn-around-time (TAT) against hospital laboratory methods.

methodsThis prospective study was carried out on 561 term-gestation jaundiced neonates in two Malaysian hospitals. Venous blood sample was collected from each neonate for contemporary measurement of TSB by hospital laboratories and Bilistick. TAT was the time interval between specimen collection and TSB result reported by each method.

resultsThe mean laboratory-measured TSB was 194.85 (±2.844) µmol/L and Bilistick TSB was 169.37 (±2.706) µmol/L. Pearson's correlation coefficient was: r = 0.901 (p < 0.001). The mean difference of [laboratory TSB- Bilistick TBS] was 26.48 (±29.41) µmol/L. The Bland-Altman plots show that the 95% limits of agreement (-31.1577, 84.11772) contain 94.7% (=531/561) of the difference in TSB readings. Bilistick has a 99% accuracy and 100% sensitivity to predict laboratory TSB levels of ≥80 µmol/L and ≥360 µmol/L at lower Bilistick TSB levels of ≥55 and ≥315 µmol/L, respectively. TAT of Bilistick TSB (2.0 min) was significantly shorter than TAT (105 min) of laboratory TSB (p < 0.001).

conclusionsBilistick has shorter TAT. The accuracy and sensitivity of Bilistick TSB for predicting laboratory TSB is high at lower cutoff levels.

Indexed as

BilirubinFemaleGestational AgeHumansHyperbilirubinemia, NeonatalInfant, NewbornJaundice, NeonatalLinear ModelsMalaysiaMaleNeonatal ScreeningPoint-of-Care SystemsProspective StudiesReproducibility of ResultsSensitivity and SpecificityTreatment OutcomeBilirubin

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.