ArticleJournal of fluorescence2019
Hydrophilic Truxene Derivative as a Fluorescent off-on Sensor for Copper (II) Ion and Phosphate Species.
Article in Journal of fluorescence, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A new symmetrical truxene derivative (TP3) containing three dipicolylamino peripheral groups is successfully synthesized in four synthetic steps with an overall yield of 42%. This hydrophilic fluorescent compound exhibits a maximum absorption wavelength at 375 nm, an emission maximum at 474 nm with an outstanding 58% quantum efficiency in THF-HEPES buffer mixture. The compound shows a highly selective fluorescence quenching towards Cu(II) ion with a detection limit of 0.06 ppm. The results from mass spectrometry and Job plot indicate that a 1:1 complex between TP3 and Cu(II) ion is responsible for the signal quenching. Interestingly, this TP3-Cu complex can be used as a turn-on sensor for hydrogen phosphate and nucleoside phosphates. The limit of detection for hydrogen phosphate is estimated at 8.7 nM. The signal restoration involves a displacement of TP3 in the complex by the phosphates which have strong coordination abilities with Cu(II) ion.
Indexed as
Identifiers
30693415What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.