Evidence map›Paper›PMID 30693406›Full record

ArticleEuropean radiology experimental2019

Biomechanical effects of osteoplasty with or without Kirschner wire augmentation on long bone diaphyses undergoing bending stress: implications for percutaneous imaging-guided consolidation in cancer patients.

Roberto Luigi Cazzato, Guillaume Koch, Julien Garnon, Nitin Ramamurthy, Jérémie Jégu, Philippe Clavert, Afshin Gangi

Abstract read
In one paragraph

Article in European radiology experimental, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Roberto Luigi CazzatoDepartment of Interventional Radiology, Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), 1, place de l'Hôpital, 67000, Strasbourg, France. gigicazzato@hotmail.it.ORCID http://orcid.org/0000-0002-6299-558X
Guillaume KochDepartment of Interventional Radiology, Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), 1, place de l'Hôpital, 67000, Strasbourg, France.
Julien GarnonDepartment of Interventional Radiology, Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), 1, place de l'Hôpital, 67000, Strasbourg, France.
Nitin RamamurthyDepartment of Radiology, Norfolk and Norwich University Hospital, Colney Lane, Norwich, NR4 7UY, UK.
Jérémie JéguLaboratoire d'Epidémiologie et de Santé Publique - EA3430, Université de Strasbourg, 4, Rue Kirschleger, 67085, Strasbourg, France.
Philippe ClavertDepartment of Normal Anatomy, Hôpitaux Universitaires de Strasbourg, HUS France, 1, place de l'Hôpital, 67000, Strasbourg, France.
Afshin GangiDepartment of Interventional Radiology, Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), 1, place de l'Hôpital, 67000, Strasbourg, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOsteoplasty has been discouraged in long bones. However, despite a substantial lack of pre-clinical biomechanical tests, multiple clinical studies have implemented a wide range of techniques to optimise long bone osteoplasty. The aim of the present study is to evaluate the biomechanical properties of osteoplasty alone and in combination with Kirschner wires (K-wires) in a cadaveric human diaphyseal model undergoing 3-point bending stress.

methodsThirty unpaired human cadaveric hemi-tibia specimens were randomly assigned to receive no consolidation (group 1, n = 10), osteoplasty alone (group 2, n = 10), or K-wires augmented osteoplasty (group 3, n = 10). Specimens were tested on a dedicated servo-hydraulic machine using a 3-point bending test. Fracture load was calculated for each specimen; two-sample Wilcoxon rank-sum tests were used to assess differences between groups.

resultsMedian volume of polymethyl methacrylate injected was 18 mL for group 2 (25th-50th percentile 15-21 mL) and 19 mL for group 3 (25th-50th percentile 17-21). There were no significant differences in fracture load between groups 1 and 2 (z = - 0.793; p = 0.430), between groups 1 and 3 (z = - 0.944; p = 0.347), and between groups 2 and 3 (z = - 0.454; p = 0.650). Fractures through the cement occurred in 4 of 30 cases (13.3%); there were no K-wires fractures.

conclusionsOsteoplasty with or without K-wires augmentation does not improve the resistance of diaphyseal bone to bending stresses.

Indexed as

Bone wiresDiaphysesFractures (bone)Polymethyl methacrylate

Identifiers

PMID30693406
PMCPMC6890912

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.