Evidence map›Paper›PMID 30691100›Full record

ArticleMicromachines2019

Measurement and Time Response of Electrohydrodynamic Direct-Writing Current.

Gaofeng Zheng, Wendong Xue, Huatan Chen, Lingling Sun, Jiaxin Jiang, Xiang Wang, Shumin Guo, Wenwang Li

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Gaofeng ZhengDepartment of Instrumental and Electrical Engineering, Xiamen University, Xiamen 361102, China. zheng_gf@xmu.edu.cn.ORCID 0000-0003-0870-6166
Wendong XueDepartment of Instrumental and Electrical Engineering, Xiamen University, Xiamen 361102, China. xwd@xmu.edu.cn.
Huatan ChenDepartment of Instrumental and Electrical Engineering, Xiamen University, Xiamen 361102, China. 35120181152283@stu.xmu.edu.cn.
Lingling SunDepartment of Instrumental and Electrical Engineering, Xiamen University, Xiamen 361102, China. lan0xuan@163.com.
Jiaxin JiangDepartment of Instrumental and Electrical Engineering, Xiamen University, Xiamen 361102, China. jiangjx@xmu.edu.cn.
Xiang WangSchool of Mechanical and Automotive Engineering, Xiamen University of Technology, Xiamen 361024, China. wx@xmut.edu.cn.ORCID 0000-0002-5718-9575
Shumin GuoFujian Provincial Key Laboratory of Mathematical Modeling and High Performance Scientific Computing, School of Mathematical Sciences, Xiamen University, Xiamen 361005, China. shumin_guo@xmu.edu.cn.
Wenwang LiSchool of Mechanical and Automotive Engineering, Xiamen University of Technology, Xiamen 361024, China. xmlww@xmut.edu.cn.
Xiamen University · CNXiamen University of Technology · CN

Funding

National Natural Science Foundation of China 51575464National Natural Science Foundation of China 51805460Natural Science Foundation of Guangdong Province 2018A030313522Science and Technology Planning Project of Fujian Province 2018J01529Science and Technology Plan of Guangzhou 201803010065Science and Technology Project of Guangdong Province 2017B090911012
6 · The paper itself

Abstract

The micro/nano current is an important characteristic to reflect the electrohydrodynamic direct-writing (EDW) process. In this paper, a direct-written current measurement system with a high signal to noise ratio was proposed to monitor the charged jets, providing the data basis for the promotion of stability and precision of the EDW jet. The electrical characteristics of the printing process were studied, the electrohydrodynamic direct-written current was associated with the stability of charged jet and the accuracy of direct-written patterns. There was an impulse current when the front end of the jet reached the collector and then a stable jet could be gained. With the increase of applied voltage, the severe fluctuation of measured current increased, the charged jet became more unstable and the accuracy of direct-written parallel lines was lower. The effects of processing parameters on direct-written current were also investigated. The average direct-written current at the stable stage increased as the applied voltage and polymer concentration increased, and it decreased as the distance from the nozzle to the collector increased. This research will promote the development and applications of EDW technology in the fields of micro/nano manufacturing.

Indexed as

direct-written currentelectrical characteristicselectrohydrodynamic direct-writingjet stabilitymicro/nano current measurement

Identifiers

PMID30691100
PMCPMC6412434
OpenAlexW2912460399

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.