ArticleJournal of controlled release : official journal of the Controlled Release Society2019
A nanoliter resolution implantable micropump for murine inner ear drug delivery.
Article in Journal of controlled release : official journal of the Controlled Release Society, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 51 citations in OpenAlex.
- Bioinspired milliscale near-boundary undulatory motion for fluid transport and adhesive locomotion.Science advances · 2026Article
- Engineered Inner Ear Drug Delivery Systems for Hearing Loss Treatment.Research (Washington, D.C.) · 2026Review
- Research Progress on Micro/Nanopore Flow Behavior.Molecules (Basel, Switzerland) · 2025Review
- L-Ergothioneine slows the progression of age-related hearing loss in CBA/CaJ mice.Hearing research · 2024Article
- Emerging biotechnologies and biomedical engineering technologies for hearing reconstruction.Smart medicine · 2023Review
- Overcoming barriers: a review on innovations in drug delivery to the middle and inner ear.Frontiers in pharmacology · 2023Review
- Long term behavior of dexamethasone-loaded cochlear implants: In vitro & in vivo.International journal of pharmaceutics: X · 2022Article
- Role of Nanomaterials in the Fabrication of bioNEMS/MEMS for Biomedical Applications and towards Pioneering Food Waste Utilisation.Nanomaterials (Basel, Switzerland) · 2022Review
- Microimaging of a novel intracochlear drug delivery device in combination with cochlear implants in the human inner ear.Drug delivery and translational research · 2022Article
- Drug Delivery across Barriers to the Middle and Inner Ear.Advanced functional materials · 2021Article
- A review of peristaltic micropumps.Sensors and actuators. A, Physical · 2021Article
- A Wirelessly Controlled Scalable 3D-Printed Microsystem for Drug Delivery.Pharmaceuticals (Basel, Switzerland) · 2021Article
- Translational implications of the interactions between hormones and age-related hearing loss.Hearing research · 2021Review
- Microtechnologies for inner ear drug delivery.Current opinion in otolaryngology & head and neck surgery · 2020Review
- Deep Volumetric Segmentation of Murine Cochlear Compartments from Micro-Computed Tomography Images.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2020Article
- A 3D-Printed Modular Microreservoir for Drug Delivery.Micromachines · 2020Article
- Recent Advances in Micro-Electro-Mechanical Devices for Controlled Drug Release Applications.Frontiers in bioengineering and biotechnology · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
Advances in protective and restorative biotherapies have created new opportunities to use site-directed, programmable drug delivery systems to treat auditory and vestibular disorders. Successful therapy development that leverages the transgenic, knock-in, and knock-out variants of mouse models of human disease requires advanced microsystems specifically designed to function with nanoliter precision and with system volumes suitable for implantation. Here we present results for a novel biocompatible, implantable, scalable, and wirelessly controlled peristaltic micropump. The micropump configuration included commercially available catheter microtubing (250 μm OD, 125 μm ID) that provided a biocompatible leak-free flow path while avoiding complicated microfluidic interconnects. Peristaltic pumping was achieved by sequentially compressing the microtubing via expansion and contraction of a thermal phase-change material located in three chambers integrated adjacent to the microtubing. Direct-write micro-scale printing technology was used to build the mechanical components of the micropump around the microtubing directly on the back of a printed circuit board assembly (PCBA). The custom PCBA was fabricated using standard commercial processes providing microprocessor control of actuation and Bluetooth wireless communication through an Android application. The results of in vitro characterization indicated that nanoliter resolution control over the desired flow rates of 10-100 nL/min was obtained by changing the actuation frequency. Applying 10× greater than physiological backpressures and ± 3 °C ambient temperature variation did not significantly affect flow rates. Three different micropumps were tested on six mice for in vivo implantation of the catheter microtubing into the round window membrane niche for infusion of a known ototoxic compound (sodium salicylate) at 50 nL/min for 20 min. Real-time shifts in distortion product otoacoustic emission thresholds and amplitudes were measured during the infusion. There were systematic increases in distortion product threshold shifts during the 20-min perfusions; the mean shift was 15 dB for the most basal region. A biocompatibility study was performed to evaluate material suitability for chronic subcutaneous implantation and clinical translational development. The results indicated that the micropump components successfully passed key biocompatibility tests. A micropump prototype was implanted for one month without development of inflammation or infection. Although tested here on the small murine cochlea, this low-cost design and fabrication methodology is scalable for use in larger animals and for clinical applications in children and adults by appropriate scaling of the microtubing diameter and actuator volume.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.