Evidence map›Paper›PMID 30690105›Full record

ArticleJournal of controlled release : official journal of the Controlled Release Society2019

A nanoliter resolution implantable micropump for murine inner ear drug delivery.

Farzad Forouzandeh, Xiaoxia Zhu, Ahmed Alfadhel, Bo Ding, Joseph P Walton, Denis Cormier, Robert D Frisina, David A Borkholder

Open access · greenAbstract readComparative Study
In one paragraph

Article in Journal of controlled release : official journal of the Controlled Release Society, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 51 citations in OpenAlex.

  1. Article
  2. Review
  3. Research Progress on Micro/Nanopore Flow Behavior.Molecules (Basel, Switzerland) · 2025
    Review
  4. Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. A review of peristaltic micropumps.Sensors and actuators. A, Physical · 2021
    Article
  12. Article
  13. Review
  14. Microtechnologies for inner ear drug delivery.Current opinion in otolaryngology & head and neck surgery · 2020
    Review
  15. Deep Volumetric Segmentation of Murine Cochlear Compartments from Micro-Computed Tomography Images.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2020
    Article
  16. Article
  17. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Farzad ForouzandehDepartment of Microsystems Engineering, Rochester Institute of Technology, Rochester, NY, USA.
Xiaoxia ZhuDepartment of Chemical & Biomedical Engineering, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL, USA.
Ahmed AlfadhelDepartment of Microsystems Engineering, Rochester Institute of Technology, Rochester, NY, USA.
Bo DingDepartment of Communication Sciences & Disorders, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL, USA.
Joseph P WaltonDepartment of Chemical & Biomedical Engineering, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL, USA; Department of Communication Sciences & Disorders, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL, USA; Department of Medical Engineering, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL, USA.
Denis CormierDepartment of Industrial and Systems Engineering, Rochester Institute of Technology, Rochester, NY, USA.
Robert D FrisinaDepartment of Chemical & Biomedical Engineering, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL, USA; Department of Communication Sciences & Disorders, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL, USA; Department of Medical Engineering, Global Center for Hearing & Speech Research, University of South Florida, Tampa, FL, USA.
David A BorkholderDepartment of Microsystems Engineering, Rochester Institute of Technology, Rochester, NY, USA. Electronic address: David.Borkholder@rit.edu.
Rochester Institute of Technology · USUniversity of South Florida · US

Funding

Enabling Microsystem Technologies for Advanced Drug DeliveryR01DC014568 · NIDCD · ROCHESTER INSTITUTE OF TECHNOLOGY · PI BORKHOLDER, DAVID A, FRISINA, ROBERT D · 2015 to 2019
$2.7M
NIDCD NIH HHS R01 DC014568
6 · The paper itself

Abstract

Advances in protective and restorative biotherapies have created new opportunities to use site-directed, programmable drug delivery systems to treat auditory and vestibular disorders. Successful therapy development that leverages the transgenic, knock-in, and knock-out variants of mouse models of human disease requires advanced microsystems specifically designed to function with nanoliter precision and with system volumes suitable for implantation. Here we present results for a novel biocompatible, implantable, scalable, and wirelessly controlled peristaltic micropump. The micropump configuration included commercially available catheter microtubing (250 μm OD, 125 μm ID) that provided a biocompatible leak-free flow path while avoiding complicated microfluidic interconnects. Peristaltic pumping was achieved by sequentially compressing the microtubing via expansion and contraction of a thermal phase-change material located in three chambers integrated adjacent to the microtubing. Direct-write micro-scale printing technology was used to build the mechanical components of the micropump around the microtubing directly on the back of a printed circuit board assembly (PCBA). The custom PCBA was fabricated using standard commercial processes providing microprocessor control of actuation and Bluetooth wireless communication through an Android application. The results of in vitro characterization indicated that nanoliter resolution control over the desired flow rates of 10-100 nL/min was obtained by changing the actuation frequency. Applying 10× greater than physiological backpressures and ± 3 °C ambient temperature variation did not significantly affect flow rates. Three different micropumps were tested on six mice for in vivo implantation of the catheter microtubing into the round window membrane niche for infusion of a known ototoxic compound (sodium salicylate) at 50 nL/min for 20 min. Real-time shifts in distortion product otoacoustic emission thresholds and amplitudes were measured during the infusion. There were systematic increases in distortion product threshold shifts during the 20-min perfusions; the mean shift was 15 dB for the most basal region. A biocompatibility study was performed to evaluate material suitability for chronic subcutaneous implantation and clinical translational development. The results indicated that the micropump components successfully passed key biocompatibility tests. A micropump prototype was implanted for one month without development of inflammation or infection. Although tested here on the small murine cochlea, this low-cost design and fabrication methodology is scalable for use in larger animals and for clinical applications in children and adults by appropriate scaling of the microtubing diameter and actuator volume.

Indexed as

Drug Delivery SystemsInfusion Pumps, ImplantableAnimalsEar, InnerEquipment DesignMiceMice, Inbred CBAMicrofluidicsSodium SalicylateSodium Salicylate3D-printingDrug deliveryInner earMicrofluidicsMicropumpMouseRound window membrane

Identifiers

PMID30690105
PMCPMC6424108
OpenAlexW2911740542

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.