Evidence map›Paper›PMID 30689216›Full record

ArticleMedical physics2019

Calibration-free beam hardening correction for myocardial perfusion imaging using CT.

Jacob Levi, Brendan L Eck, Rachid Fahmi, Hao Wu, Mani Vembar, Amar Dhanantwari, Anas Fares, Hiram G Bezerra, David L Wilson

Open access · hybridAbstract read
In one paragraph

Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Jacob LeviDepartment of Physics, Case Western Reserve University, Cleveland, OH, 44106, USA.
Brendan L EckDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA.
Rachid FahmiResearch and Clinical Collaborations, Siemens Healthineers, Knoxville, TN, USA.
Hao WuDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA.
Mani VembarPhilips Healthcare, Cleveland, OH, 44143, USA.
Amar DhanantwariPhilips Healthcare, Cleveland, OH, 44143, USA.
Anas FaresCardiovascular Imaging Core Laboratory, Harrington Heart & Vascular Institute, University Hospitals Case Medical Center, Cleveland, OH, 44106, USA.
Hiram G BezerraCardiovascular Imaging Core Laboratory, Harrington Heart & Vascular Institute, University Hospitals Case Medical Center, Cleveland, OH, 44106, USA.
David L WilsonDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA.
Case Western Reserve University · USPhilips (United States) · USUniversity Hospitals Case Medical Center · USSiemens Healthcare (United States) · US

Funding

Interdisciplinary Biomedical Imaging Training ProgramT32EB007509 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI DAVID Lynn WILSON, Xin Yu · 2007 to 2026
$5.6M
System-independent quantitative cardiac CT perfusionR44HL156811 · NHLBI · BIOINVISION, INC. · PI ROY, DEBASHISH, WILSON, DAVID LYNN · 2021 to 2022
$2.0M
In vivo Characterization of Stents using Intravascular OCT ImagingR01HL114406 · NHLBI · CASE WESTERN RESERVE UNIVERSITY · PI BEZERRA, HIRAM, ROLLINS, ANDREW MARTIN · 2013 to 2016
$1.7M
System-independent quantitative cardiac CT perfusionR41HL144271 · NHLBI · BIOINVISION, INC. · PI WILSON, DAVID LYNN · 2018 to 2018
$224k
Interdisciplinary Biomedical Imaging Training Program T32EB007509NHLBI NIH HHS R01 HL114406NHLBI NIH HHS R41 HL144271NHLBI NIH HHS R44 HL156811NIBIB NIH HHS T32 EB007509Ohio Third Frontier
6 · The paper itself

Abstract

purposeComputed tomography myocardial perfusion imaging (CT-MPI) and coronary CTA have the potential to make CT an ideal noninvasive imaging gatekeeper exam for invasive coronary angiography. However, beam hardening (BH) artifacts prevent accurate blood flow calculation in CT-MPI. BH correction methods require either energy-sensitive CT, not widely available, or typically, a calibration-based method in conventional CT. We propose a calibration-free, automatic BH correction (ABHC) method suitable for CT-MPI and evaluate its ability to reduce BH artifacts in single "static-perfusion" images and to create accurate myocardial blood flow (MBF) in dynamic CT-MPI.

methodsIn the algorithm, we used input CT DICOM images and iteratively optimized parameters in a polynomial BH correction until a BH-sensitive cost function was minimized on output images. An input image was segmented into a soft tissue image and a highly attenuating material (HAM) image containing bones and regions of high iodine concentrations, using mean HU and temporal enhancement properties. We forward projected HAM, corrected projection values according to a polynomial correction, and reconstructed a correction image to obtain the current iteration's BH corrected image. The cost function was sensitive to BH streak artifacts and cupping. We evaluated the algorithm on simulated CT and physical phantom images, and on preclinical porcine with optional coronary obstruction and clinical CT-MPI data. Assessments included measures of BH artifact in single images as well as MBF estimates. We obtained CT images on a prototype spectral detector CT (SDCT, Philips Healthcare) scanner that provided both conventional and virtual keV images, allowing us to quantitatively compare corrected CT images to virtual keV images. To stress test the method, we evaluated results on images from a different scanner (iCT, Philips Healthcare) and different kVp values.

resultsIn a CT-simulated digital phantom consisting of water with iodine cylinder insets, BH streak artifacts between simulated iodine inserts were reduced from 13 ± 2 to 0 ± 1 HU. In a similar physical phantom having higher iodine concentrations, BH streak artifacts were reduced from 48 ± 6 to 1 ± 5 HU and cupping was reduced by 86%, from 248 to 23 HU. In preclinical CT-MPI images without coronary obstruction, BH artifact was reduced from 24 ± 6 HU to less than 5 ± 4 HU at peak enhancement. Standard deviation across different regions of interest (ROI) along the myocardium was reduced from 13.26 to 6.86 HU for ABHC, comparing favorably to measurements in the corresponding virtual keV image. Corrections greatly reduced variations in preclinical MBF maps as obtained in normal animals without obstruction (FFR = 1). Coefficients of variations were 22% (conventional CT), 9% (ABHC), and 5% (virtual keV). Moreover, variations in flow tended to be localized after ABHC, giving result which would not be confused with a flow deficit in a coronary vessel territory.

conclusionThe automated algorithm can be used to reduce BH artifact in conventional CT and improve CT-MPI accuracy particularly by removing regions of reduced estimated flow which might be misinterpreted as flow deficits.

Indexed as

AlgorithmsPhantoms, ImagingAnimalsCalibrationCoronary OcclusionFemaleMyocardial Perfusion ImagingRadiographic Image EnhancementRadiographic Image Interpretation, Computer-AssistedSwineTomography, X-Ray Computedbeam hardening correctioncardiovascular imagingCTMPI-CTmyocardial perfusion

Identifiers

PMID30689216
PMCPMC6453761
OpenAlexW2912099219

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.