ArticleAnnals of biomedical engineering2019
Efficacy of Sonothrombolysis Using Microbubbles Produced by a Catheter-Based Microfluidic Device in a Rat Model of Ischemic Stroke.
Article in Annals of biomedical engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 27 citations in OpenAlex.
- PA System in the Pathogenesis of Ischemic Stroke.Arteriosclerosis, thrombosis, and vascular biology · 2025Review
- Focused Ultrasound: Noninvasive Image-Guided Therapy.Investigative radiology · 2025Review
- Sonothrombolysis Using Microfluidically Produced Microbubbles in a Murine Model of Deep Vein Thrombosis.Annals of biomedical engineering · 2025Article
- Beyond silence: evolving ultrasound strategies in the battle against cardiovascular thrombotic challenges.Journal of thrombosis and thrombolysis · 2024Review
- Dual-mode nanoprobe strategy integrating ultrasound and near-infrared light for targeted and synergistic arterial thrombolysis.Journal of nanobiotechnology · 2024Article
- Sonothrombolysis for Ischemic Stroke.Journal of cardiovascular development and disease · 2024Review
- Sonothrombolysis: State-of-the-Art and Potential Applications in Children.Children (Basel, Switzerland) · 2023Review
- Low-Intensity Ultrasound Reduces Brain Infarct Size by Upregulating Phosphorylated Endothelial Nitric Oxide in Mouse Model of Middle Cerebral Artery Occlusion.Ultrasound in medicine & biology · 2023Article
- Microbubble-Nanoparticle Complexes for Ultrasound-Enhanced Cargo Delivery.Pharmaceutics · 2022Review
- A Fibrinogen-Mimicking, Activated-Platelet-Sensitive Nanocoacervate Enhances Thrombus Targeting and Penetration of Tissue Plasminogen Activator for Effective Thrombolytic Therapy.Advanced healthcare materials · 2022Article
- Recent Advances in Cardiac Tissue Engineering for the Management of Myocardium Infarction.Cells · 2021Review
- Microbubble-mediated sonothrombolysis with BR38 of a venous full blood thrombus in a rat embolic stroke model.Annals of translational medicine · 2021Article
- Ultrasound-Responsive Cavitation Nuclei for Therapy and Drug Delivery.Ultrasound in medicine & biology · 2020Review
- Closed-loop feedback control of microbubble diameter from a flow-focusing microfluidic device.Biomicrofluidics · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
Limitations of existing thrombolytic therapies for acute ischemic stroke have motivated the development of catheter-based approaches that utilize no or low doses of thrombolytic drugs combined with a mechanical action to either dissolve or extract the thrombus. Sonothrombolysis accelerates thrombus dissolution via the application of ultrasound combined with microbubble contrast agents and low doses of thrombolytics to mechanically disrupt the fibrin mesh. In this work, we studied the efficacy of catheter-directed sonothrombolysis in a rat model of ischemic stroke. Microbubbles of 10-20 µm diameter with a nitrogen gas core and a non-crosslinked albumin shell were produced by a flow-focusing microfluidic device in real time. The microbubbles were dispensed from a catheter located in the internal carotid artery for direct delivery to the thrombus-occluded middle cerebral artery, while ultrasound was administered through the skull and recombinant tissue plasminogen activator (rtPA) was infused via a tail vein catheter. The results of this study demonstrate that flow focusing microfluidic devices can be miniaturized to dimensions compatible with human catheterization and that large-diameter microbubbles comprised of high solubility gases can be safely administered intraarterially to deliver a sonothrombolytic therapy. Further, sonothrombolysis using intraarterial delivery of large microbubbles reduced cerebral infarct volumes by approximately 50% vs. no therapy, significantly improved functional neurological outcomes at 24 h, and permitted rtPA dose reduction of 3.3 (95% CI 1.8-3.8) fold when compared to therapy with intravenous rtPA alone.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.