Evidence map›Paper›PMID 30686948›Full record

ArticleJournal of Korean medical science2019

Carbon-Fiber Based Microelectrode Array Embedded with a Biodegradable Silk Support for In Vivo Neural Recording.

Yena Lee, Chanho Kong, Jin Woo Chang, Sang Beom Jun

Abstract read
In one paragraph

Article in Journal of Korean medical science, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Fabrication and Validation of Sub-Cellular Carbon Fiber Electrodes.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2024
    Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yena LeeDepartment of Electronic and Electrical Engineering, ELTEC College of Engineering, Ewha Womans University, Seoul, Korea.ORCID https://orcid.org/0000-0001-7237-0594
Chanho KongDepartment of Neurosurgery, Yonsei University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-7987-7689
Jin Woo ChangDepartment of Neurosurgery, Yonsei University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-2717-0101
Sang Beom JunDepartment of Electronic and Electrical Engineering, ELTEC College of Engineering, Ewha Womans University, Seoul, Korea.ORCID https://orcid.org/0000-0003-3912-250X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRecently, carbon fibers have been utilized to develop a depth-type microelectrode array for chronic neural recording. Since the diameter of carbon fibers is smaller than the conventional electrodes made of metal wires or microfabricated silicon, the carbon fiber electrodes showed an improved capability for chronic neural recording with less tissue damages. However, the carbon fiber based microelectrodes have a limitation of short insertion depth due to a low stiffness.

methodsWe proposed a carbon fiber based microelectrode array embedded with a mechanical support structure to facilitate the penetration into the deeper brain. The support is made of biodegradable silk fibroin to reduce the reactive tissue responses. The 4-channel carbon fiber based microelectrode arrays were fabricated and accessed in terms of electrochemical impedance, recording capability for 1-month implantation in rat hippocampi. The electrodes with tungsten supports were fabricated and tested as a control group. Immunohistochemical analysis was performed to identify the reactive glial responses.

resultsThe carbon fiber based electrode arrays with silk supports showed about 2-fold impedance increase 2 weeks after implantation while the number of active electrodes decreased simultaneously. However, after 1 month, the electrode impedance decreased back to its initial value and the percentage of active electrodes also increased above 70%. Immunohistochemical staining clearly showed that the electrodes with silk supports induced less reactive glial responses than that with tungsten supports.

conclusionThe proposed carbon fiber based microelectrode array is expected to be used for long-term in vivo neural recording from deep brain regions with the minimized reactive tissue response.

Indexed as

Absorbable ImplantsAnimalsBrainCarbon FiberElectric ImpedanceElectrocorticographyElectrodes, ImplantedMaleMicroelectrodesNeuronsRatsRats, Sprague-DawleySignal Processing, Computer-AssistedSignal-To-Noise RatioSilkCarbon FiberSilkCarbon FiberNeural RecordingSilk FibroinTissue Response

Identifiers

PMID30686948
PMCPMC6345632

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.