Evidence map›Paper›PMID 30684237›Full record

ArticleRadiological physics and technology2019

Validation of secondary dose calculation system with manufacturer-provided reference beam data using heterogeneous phantoms.

Yuji Nakaguchi, Yuya Nakamura, Yohei Yotsuji

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yuji NakaguchiDepartment of Radiological Technology, Kumamoto University Hospital, 1-1-1 Honjyo, Kumamoto, Japan. nakaguchi@kuh.kumamoto-u.ac.jp.ORCID http://orcid.org/0000-0002-1016-9921
Yuya NakamuraDepartment of Radiological Technology, Kumamoto University Hospital, 1-1-1 Honjyo, Kumamoto, Japan.
Yohei YotsujiDepartment of Radiological Technology, Kumamoto University Hospital, 1-1-1 Honjyo, Kumamoto, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Mobius3D (M3D) system (Mobius Medical Systems) is a second-check dosimetry system. We investigated the dose calculation accuracy of this system using heterogeneous phantoms with reference beam data provided by the manufacturer using simple and patient plans. We compared the dose distributions between M3D and the treatment planning system, as well as the measurements in solid water phantoms, heterogeneous phantoms, and patient plans for Varian and Elekta accelerators. The M3D results agreed well with the measurements in the solid water phantoms for the simple plans. However, the accuracy of M3D appeared to depend on the type of accelerator, as indicated by the slight differences in the dose measurements. Furthermore, the M3D dose measurements differed by 5-10% in the lung and bone regions. Regarding the patient plans, we confirmed that M3D is reasonably accurate as a second-check system, despite the slight accelerator type-dependent dose difference.

Indexed as

Phantoms, ImagingRadiation DosageHumansRadiometryRadiotherapy Planning, Computer-AssistedDose verificationQuality assuranceReference beam dataSecond-check dosimetry systemVolumetric modulated arc therapy

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.