Evidence map›Paper›PMID 30682826›Full record

ArticleMaterials (Basel, Switzerland)2019

A Literature Review Study on Atomic Ions Dissolution of Titanium and Its Alloys in Implant Dentistry.

Sammy Noumbissi, Antonio Scarano, Saurabh Gupta

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 60 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
60citing papers in PubMed, 2 pooled it
20.5field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

60 citing papers in PubMed, 2 syntheses or guidelines pooled it, 154 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Review
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Review
  14. Article
  15. Tribocorrosion of 3D printed dental implants: An overview.Journal of Taibah University Medical Sciences · 2024
    Review
  16. Review
  17. Review
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Sammy NoumbissiInternational Academy of Ceramic Implantology, Silver Spring, MD 20910, USA. sammy@iaoci.com.ORCID 0000-0001-5023-3265
Antonio ScaranoDepartment of Medical, Oral and Biotechnological Sciences and CeSi Met, University of Chieti-Pescara, 66100 Chieti, Italy. ascarano@unich.it.ORCID 0000-0003-1374-6146
Saurabh GuptaInternational Academy of Ceramic Implantology, Silver Spring, MD 20910, USA. saurabh@iaoci.com.
University of Chieti-Pescara · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This review of literature paper was done in order to conduct a review of the literature and an assessment of the effects of titanium implant corrosion on peri-implant health and success in the oral environment. This paper evaluates and critically reviews the findings of the multiple in-depth in vivo and in vitro studies that are related to corrosion aspects of the titanium and its alloys. A literature survey was conducted by electronic search in Medline and studies that were published between 1940 and August 2018 were selected. The search terms used were types of corrosion, corrosion of titanium implants, titanium corrosion, metal ion release from the titanium implants, fretting and pitting corrosion, implant corrosion, peri implantitis, and corrosion. Both in vivo and in vitro studies were also included in the review. The search and selection resulted in 64 articles. These articles were divided on the basis of their context to different kinds of corrosion related to titanium dental implants. It is evident that metal ions are released from titanium and titanium alloy dental implants as a result of corrosion. Corrosion of implants is multifactorial, including electrical, chemical, and mechanical factors, which have an effect on the peri-implant tissues and microbiota. The literature surveyed showed that corrosion related to titanium and its alloys has an effect on the health of peri-implant soft and hard tissue and the long term survival of metal dental implants. It can be concluded that presence of the long-term corrosion reaction along with continuous corrosion leads to the release of ions into the peri-implant tissue but also to a disintegration of the implant that contribute to material fatigue and even fracture of the abutments and implant body or both. This combined impact of the corrosion, bacterial activity, chemical reactions, and functional stresses are to be looked at as important factors of implant failure. The findings can be used to explore the possible strategies of research to investigate the biological impact of implant materials.

Indexed as

corrosion of titanium implantscrestal bone resorptionfretting and pitting corrosionimplant corrosionmetal ion release from the titanium implantsperi implantitis and corrosiontitanium corrosion

Identifiers

PMID30682826
PMCPMC6384935
OpenAlexW2913286657

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.