Evidence map›Paper›PMID 30681622›Full record

SynthesisMedicine2019

Contrast-enhanced ultrasound for evaluating the pathologic response of breast cancer to neoadjuvant chemotherapy: A meta-analysis.

Kun Jia, Li Li, Xiao Jing Wu, Mei Jin Hao, Hong Yuan Xue

Abstract readMeta-Analysis
In one paragraph

Synthesis in Medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Guideline
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Observational
  13. Review
  14. Review
  15. Article
  16. Review
  17. What scans we will read: imaging instrumentation trends in clinical oncology.Cancer imaging : the official publication of the International Cancer Imaging Society · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kun JiaDepartment of Ultrasound, Hebei General Hospital, Heping West Road, XinHua Qu, Shijiazhuang, China.
Li Li
Xiao Jing Wu
Mei Jin Hao
Hong Yuan Xue

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveRecent reports have suggested that contrast-enhanced ultrasound (CEUS) can be used to monitor the pathologic responses of breast cancer (BC) to neoadjuvant chemotherapy (NAC); however, the diagnostic performance of CEUS in BC has yet to be confirmed. Thus, we conducted a meta-analysis of related studies to explore the relationship between CEUS and pathologic responses of BC to NAC. MATERIALS AND

methodsWe searched PubMed, Embase, Web of Science, ScienceDirect, and China National Knowledge Infrastructure databases for studies published until September 31, 2018. Study-specific odds ratios (ORs) and 95% confidence intervals (CIs) were calculated, and then ORs with 95% CIs were pooled to estimate the prognostic role of CEUS for the pathologic responses of BC to NAC.

resultsPooled meta-analysis of the 9 eligible studies that included 424 patients indicated the high performance of CEUS for monitoring pathologic responses to NAC (OR = 31.83, 95% CI: 16.69-60.67, P < .001), with no significant heterogeneity (I = 0.0%, P = .529). The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 87% (95% CI: 0.81-0.92), 84% (95% CI: 0.74-0.91), 5.5 (95% CI: 3.3-9.2), 0.15 (95% CI: 0.10-0.23), and 36 (95% CI: 18-70), respectively. An area under the curve of 0.92 (95% CI: 0.89-0.94) suggests a high ability for prognostic detection. Although Begg's funnel plot (P = .057) indicated the presence of publication bias among the included studies, the trim-and-fill method verified the stability of the pooled outcomes. Sensitivity analysis suggested that the pooled OR was robust.

conclusionOur results suggest that CEUS has a high diagnostic performance for the pathologic responses of BC to NAC. Further and better-designed studies should be performed to verify the clinical applications of CEUS for monitoring BC responses to NAC.

Indexed as

Contrast MediaAdultAntineoplastic AgentsBreast NeoplasmsChemotherapy, AdjuvantFemaleHumansMiddle AgedNeoadjuvant TherapyOdds RatioOutcome Assessment, Health CareSensitivity and SpecificityTreatment OutcomeUltrasonographyAntineoplastic AgentsContrast Media

Identifiers

PMID30681622
PMCPMC6358361

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.