ArticleAJNR. American journal of neuroradiology2019
Ostium Ratio and Neck Ratio Could Predict the Outcome of Sidewall Intracranial Aneurysms Treated with Flow Diverters.
Article in AJNR. American journal of neuroradiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- Application of machine learning algorithms to predict and assess factors related to internal carotid siphon aneurysm occlusion treated with flow diversion.Neuroradiology · 2026Article
- Comparative safety, efficacy, and predictors of complete occlusion of flow diverter devices in the treatment of unruptured distal anterior cerebral artery aneurysms.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2026Article
- Factors Associated with Aneurysm Occlusion after Flow Diverter Treatment.Journal of neuroendovascular therapy · 2026Review
- Imaging of Intracranial Aneurysms: A Review of Standard and Advanced Imaging Techniques.Translational stroke research · 2025Review
- Exploration of the effect of morphology and location on hemodynamics of small aneurysms: a variable-controlled study based on two cases with tandem aneurysms.Biomedical engineering online · 2025Article
- Prediction and SHAP Analysis Integrating Morphological and Hemodynamic Parameters for Unruptured Intracranial Aneurysm Occlusion After Flow Diverter Treatment.CNS neuroscience & therapeutics · 2025Article
- Predictive Methods for Thrombus Formation in the Treatment of Aortic Dissection and Cerebral Aneurysms: A Comprehensive Review.Bioengineering (Basel, Switzerland) · 2024Review
- Aneurysm Isolation is Associated with Complete Occlusion of Aneurysms After Flow Diverter Treatment.Clinical neuroradiology · 2023Article
- Persistent Opacification of the Woven EndoBridge Device: A Conebeam CT Analysis of the Bicêtre Occlusion Scale Score 1 Phenomenon.AJNR. American journal of neuroradiology · 2023Article
- Rupture discrimination of multiple small (< 7 mm) intracranial aneurysms based on machine learning-based cluster analysis.BMC neurology · 2023Article
- Prediction of atherosclerotic changes in cavernous carotid aneurysms based on computational fluid dynamics analysis: a proof-of-concept study.Neuroradiology · 2022Article
- Definition and extraction of 2D shape indices of intracranial aneurysm necks for rupture risk assessment.International journal of computer assisted radiology and surgery · 2021Article
- Automated Machine Learning Model Development for Intracranial Aneurysm Treatment Outcome Prediction: A Feasibility Study.Frontiers in neurology · 2021Article
- 2D parametric contrast time-density analysis for the prediction of complete aneurysm occlusion at six months' post-flow diversion stent.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2020Article
- Aneurysm characteristics, coil packing, and post-coiling hemodynamics affect long-term treatment outcome.Journal of neurointerventional surgery · 2020Article
- Large Neck and Strong Ostium Inflow as the Potential Causes for Delayed Occlusion of Unruptured Sidewall Intracranial Aneurysms Treated by Flow Diverter.AJNR. American journal of neuroradiology · 2020Article
- Outcome prediction of intracranial aneurysm treatment by flow diverters using machine learning.Neurosurgical focus · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
Abstract
background and purposeIncompletely occluded flow diverter treated aneurysms remain at risk of rupture and thromboembolic complications. Our aim was to identify the potential for incomplete occlusion of intracranial aneurysms treated by flow diverters. We investigated whether aneurysm ostium size in relation to parent artery size affects angiographic outcomes of flow diverter-treated sidewall aneurysms. MATERIALS AND
methodsFlow diverter-treated sidewall aneurysms were divided into "occluded" and "residual" (incomplete occlusion) groups based on 6-month angiographic follow-up. We calculated the ostium ratio, a new parameter defined as the aneurysm ostium surface area versus the circumferential surface area of the parent artery. We also calculated the neck ratio, defined as clinical aneurysm neck diameter versus parent artery diameter from pretreatment 2D DSA, as a 2D surrogate. We compared the performance of these ratios with existing aneurysm morphometrics (size, neck diameter, volume, aspect ratio, size ratio, undulation index, nonsphericity index, ellipticity index, bottleneck factor, aneurysm angle, and parent vessel angle) and flow diverter-related parameters (metal coverage rate and pore density). Statistical tests and receiver operating characteristic analyses were performed to identify significantly different parameters between the 2 groups and test their predictive performances.
resultsWe included 63 flow diverter-treated aneurysms, 46 occluded and 17 residual. The ostium ratio and neck ratio were significantly higher in the residual group than in the occluded group (
conclusionsHigh ostium ratios and neck ratios could predict incomplete occlusion of flow diverter-treated sidewall aneurysms. Neck ratio can be easily calculated by interventionists to predict flow-diverter treatment outcomes.