Radiation dose and image quality comparison during spine surgery with two different, intraoperative 3D imaging navigation systems.

Rami Nachabe, Keith Strauss, Beth Schueler, Mohamad Bydon

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 2 pooled it
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 2 syntheses or guidelines pooled it, 37 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Usefulness of portrait imaging for intraoperative cone beam computed tomography in adolescent idiopathic scoliosis surgery: a phantom study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. [Camera-based navigation in the hybrid operating room].Chirurgie (Heidelberg, Germany) · 2023
    Review
  8. Article
  9. Review
  10. Article
  11. Vertebrae segmentation in reduced radiation CT imaging for augmented reality applications.International journal of computer assisted radiology and surgery · 2022
    Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Rami NachabeImage Guided Therapy Systems, Philips Healthcare, Best, The Netherlands.
Keith StraussDepartment of Radiology, Cincinnati Children's Hospital, Cincinnati, OH, USA.
Beth SchuelerDepartment of Neurologic Radiology, Mayo Clinic, Rochester, MN, USA.
Mohamad BydonDepartment of Neurologic Surgery, Mayo Clinic, Rochester, MN, USA.
Mayo Clinic · USCincinnati Children's Hospital Medical Center · USPhilips (Netherlands) · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Careful protocol selection is required during intraoperative three-dimensional (3D) imaging for spine surgery to manage patient radiation dose and achieve clinical image quality. Radiation dose and image quality of a Medtronic O-arm commonly used during spine surgery, and a Philips hybrid operating room equipped with XperCT C-arm 3D cone-beam CT (hCBCT) are compared. The mobile O-arm (mCBCT) offers three different radiation dose settings (low, standard, and high), for four different patient sizes (small, medium, large, and extra large). The patient's radiation dose rate is constant during the entire 3D scan. In contrast, C-CBCT spine imaging uses three different field of views (27, 37, and 48 cm) using automatic exposure control (AEC) that modulates the patient's radiation dose rate during the 3D scan based on changing patient thickness. hCBCT uses additional x-ray beam filtration. Small, medium, and large trunk phantoms designed to mimic spine and soft tissue were imaged to assess radiation dose and image quality of the two systems. The estimated measured "patient" dose for the small, medium, and large phantoms imaged by the mCBCT considering all the dose settings ranged from 9.4-27.6 mGy, 8.9-33.3 mGy, and 13.8-40.6 mGy, respectively. The "patient" dose values for the same phantoms imaged with hCBCT were 2.8-4.6 mGy, 5.7-10.0 mGy, and 11.0-15.2 mGy. The CNR for the small, medium, and large phantoms was 2.9 to 3.7, 2.0 to 3.0, and 2.5 to 2.6 times higher with the hCBCT system, respectively. Hounsfield unit accuracy, noise, and uniformity of hCBCT exceeded the performance of the mCBCT; spatial resolution was comparable. Added x-ray beam filtration and AEC capability achieved clinical image quality for intraoperative spine surgery at reduced radiation dose to the patient in comparison to a reference O-arm system without these capabilities.

Indexed as

Phantoms, ImagingCone-Beam Computed TomographyHumansImage Processing, Computer-AssistedImaging, Three-DimensionalIntraoperative CareOrgans at RiskRadiation DosageRadiosurgeryRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedSpinal NeoplasmsSurgery, Computer-Assistedcone-beam CTimage qualityintraoperative 3D imagingradiation dosespine surgery

Identifiers

PMID30677233
PMCPMC6370984
OpenAlexW2913776163

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.