Characterization of a prototype rapid kilovoltage x-ray image guidance system designed for a ring shape radiation therapy unit.

Bin Cai, Eric Laugeman, Thomas R Mazur, Justin C Park, Lauren E Henke, Hyun Kim, Geoffrey D Hugo, Sasa Mutic, Hua Li

Open access · bronzeAbstract read
In one paragraph

Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 62 papers.

0numbers the graph read from it
0cells of the map it votes in
62citing papers in PubMed
15.0field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

62 citing papers in PubMed, 100 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article

2 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Bin CaiDepartment of Radiation Oncology, Washington University, St. Louis, MO, 63110, USA.
Eric LaugemanDepartment of Radiation Oncology, Washington University, St. Louis, MO, 63110, USA.
Thomas R MazurDepartment of Radiation Oncology, Washington University, St. Louis, MO, 63110, USA.
Justin C ParkDepartment of Radiation Oncology, Washington University, St. Louis, MO, 63110, USA.
Lauren E HenkeDepartment of Radiation Oncology, Washington University, St. Louis, MO, 63110, USA.
Hyun KimDepartment of Radiation Oncology, Washington University, St. Louis, MO, 63110, USA.
Geoffrey D HugoDepartment of Radiation Oncology, Washington University, St. Louis, MO, 63110, USA.
Sasa MuticDepartment of Radiation Oncology, Washington University, St. Louis, MO, 63110, USA.
Hua LiDepartment of Radiation Oncology, Washington University, St. Louis, MO, 63110, USA.
Washington University in St. Louis · US

Funding

Multimodal Biomarkers For Oropharyngeal CancerR01CA233873 · NCI · WASHINGTON UNIVERSITY · PI LI, HUA · 2019 to 2024
$2.0M
NCI NIH HHS R01 CA233873
6 · The paper itself

Abstract

purposeThis study aims to characterize the performance of a prototype rapid kilovoltage (kV) x-ray image guidance system onboard the newly released Halcyon 2.0 linear accelerator (Varian Medical Systems, Palo Alto, CA) by use of conventional and innovatively designed testing procedures.

methodsBasic imaging system performance tests and radiation dose measurements were performed for all eleven kV-cone beam computed tomography (CBCT) imaging protocols available on a preclinical Halcyon 2.0 LINAC. Both conventional CBCT reconstruction using the Feldkamp-Davis-Kress (FDK) algorithm and a novel, advanced iterative reconstruction (iCBCT) available on this platform were evaluated. Standard image quality metrics, including slice thickness accuracy, high-contrast resolution, low-contrast resolution, regional uniformity and noise, and CT Hounsfield unit (HU) number accuracy and linearity were evaluated using a manufacturer-supplied QUART phantom (GmbH, Zorneding, Germany) and an independent image quality phantom (Catphan 500, The Phantom Laboratory, New York, NY). Due to the simplified design of the QUART phantom, we developed surrogate and clinically feasible strategies for measuring slice thickness and high- and low-contrast resolution. Imaging dose delivered by these eleven protocols was measured using a computed tomography dose index phantom and pencil chamber with commonly accepted methods and procedures. A subset of measurements were repeated on a conventional C-arm LINAC (TrueBeam and Trilogy, Varian Medical System) for comparison. Clinical patient images of pelvic and abdominal regions are also presented for qualitative assessment as part of a feasibility study for clinical implementation.

resultsImage acquisition time was 17-42 s on the Halcyon system compared with 60 s on the C-arm LINAC systems. The kV imager projection offset, imaging and treatment isocenter coincidence and the couch three-dimensional match movement all achieved less than1 mm mechanical accuracy. All major image quality metrics were within either the national guideline or vendor-recommended tolerances. The designed surrogate approach with the QUART phantom showed a range of 0.24-0.35 cycles/mm for spatial resolution, a contrast-to-noise ratio (CNR) of 2-20 for FDK reconstruction and a tolerance of 0.5 mm for slice thickness. Other metrics derived from the Catphan images obtained on the Halcyon and C-arm LINACs showed comparable values for the FDK reconstruction. The iterative reconstruction tended to reduce noise, as evidenced by a higher CNR ratio. The fast scan pelvis protocols for Halcyon resulted in 50% lower dose compared to the standard scans, and the thorax fast protocol similarly delivered 10% lower dose than the standard thoracic scan. Preliminary patient images indicated that rapid kV CBCT with breath-hold is feasible, with improved imaging quality compared to free-breathing scans.

conclusionIndependent and comprehensive characterization of the kV imaging guidance system on the Halcyon 2.0 system demonstrated acceptable image quality for clinical use. The imaging unit onboard the Halcyon meets vendor specifications and satisfies requirements for routine clinical use. The fast kV imaging system enables the potential for volumetric CBCT acquisition during a single breath-hold and the iterative reconstruction tends to reduce the noise therefore has the potential to improve the CNR for normal size patient.

Indexed as

Phantoms, ImagingAbdominal NeoplasmsAlgorithmsCone-Beam Computed TomographyFeasibility StudiesHumansImage Processing, Computer-AssistedParticle AcceleratorsPelvic NeoplasmsRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedX-Raysfast CBCT imagingKV-IGRTring gantry LINAC

Identifiers

PMID30675902
PMCPMC8188470
OpenAlexW2912251332

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.