Characterization of a prototype rapid kilovoltage x-ray image guidance system designed for a ring shape radiation therapy unit.
Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 62 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
62 citing papers in PubMed, 100 citations in OpenAlex.
- HyperSight CBCT image quality and metal artifact reduction for adaptive head and neck radiotherapy: Results from a prospective clinical trial.Journal of applied clinical medical physics · 2025Trial
- Benchmarking halcyon ring delivery system for hypofractionated breast radiotherapy: Validation and clinical implementation of the fast-forward trial.Journal of applied clinical medical physics · 2023Trial
- External evaluation of a deep learning-based algorithm for automated lung tumor and esophagus segmentation on CBCT.Biomedical physics & engineering express · 2026Article
- Evaluating Image Quality of Cone Beam Computed Tomography Using HyperSight® on the Varian TrueBeam.Annals of biomedical engineering · 2026Article
- Quantitative assessment of CBCT image quality metrics and their translation to clinical Art workflow performance in breast cancer patients.Journal of applied clinical medical physics · 2026Article
- First evaluation of in-patient dose calculation accuracy on a C-arm Linear Accelerator with advanced Cone-Beam computed tomography (CBCT) imaging.Physics and imaging in radiation oncology · 2026Article
- Characterization and Clinical Translation of a Novel Prototype Kilovoltage Dual-Layer Imager for Onboard Imaging.International journal of radiation oncology, biology, physics · 2026Article
- Multispectral PCCT and CBCT imaging for high precision radiotherapy through translation of imaging parameters with machine learning validation.Scientific reports · 2026Article
- Article
- Palliative expeditiously adaptive quad shot radiotherapy for head and neck cancers (PEAQ-RT).Clinical and translational radiation oncology · 2025Article
- Hounsfield Unit characterization and dose calculation on a C-arm linac with novel on-board cone-beam computed tomography feature and advanced reconstruction algorithms.Journal of applied clinical medical physics · 2025Article
- Super-resolution CBCT on a new generation flat panel imager of a C-arm gantry linear accelerator.Medical physics · 2025Article
- Quantification and dosimetric impact of intra-fractional bladder changes during CBCT-guided online adaptive radiotherapy for pelvic cancer treatments.Journal of applied clinical medical physics · 2025Article
- An investigation into the feasibility and efficacy of stereotactic radiosurgery for 1-3 cm single brain lesions on the ring-mounted Halcyon LINAC.Journal of applied clinical medical physics · 2025Article
- Characterization of a prototype rapid kilovoltage x-ray image guidance system designed for a linear accelerator radiation therapy unit.Journal of applied clinical medical physics · 2025Article
- Dose calculation accuracy of clinical radiotherapy plans using next generation cone beam computed tomography imaging technology.Physics and imaging in radiation oncology · 2025Article
- Comprehensive Image Quality Evaluation and Motion Phantom Studies of an Ultra-Fast (6-Second) Cone-Beam Computed Tomography Imaging System on a Ring Gantry Linear Accelerator.Advances in radiation oncology · 2025Article
- Dosimetric comparison of Monte Carlo, Acuros XB, and anisotropic analytical algorithm for lung cancer plans on halcyon accelerators.PloS one · 2025Article
- Comparative analysis of VMAT plans on Halcyon and infinity for lung cancer radiotherapy.PloS one · 2025Article
- Characterization of kilovoltage x-ray image guidance system with a novel post-processing algorithm on a new slip ring-mounted radiotherapy system.Journal of applied clinical medical physics · 2024Article
2 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
Abstract
purposeThis study aims to characterize the performance of a prototype rapid kilovoltage (kV) x-ray image guidance system onboard the newly released Halcyon 2.0 linear accelerator (Varian Medical Systems, Palo Alto, CA) by use of conventional and innovatively designed testing procedures.
methodsBasic imaging system performance tests and radiation dose measurements were performed for all eleven kV-cone beam computed tomography (CBCT) imaging protocols available on a preclinical Halcyon 2.0 LINAC. Both conventional CBCT reconstruction using the Feldkamp-Davis-Kress (FDK) algorithm and a novel, advanced iterative reconstruction (iCBCT) available on this platform were evaluated. Standard image quality metrics, including slice thickness accuracy, high-contrast resolution, low-contrast resolution, regional uniformity and noise, and CT Hounsfield unit (HU) number accuracy and linearity were evaluated using a manufacturer-supplied QUART phantom (GmbH, Zorneding, Germany) and an independent image quality phantom (Catphan 500, The Phantom Laboratory, New York, NY). Due to the simplified design of the QUART phantom, we developed surrogate and clinically feasible strategies for measuring slice thickness and high- and low-contrast resolution. Imaging dose delivered by these eleven protocols was measured using a computed tomography dose index phantom and pencil chamber with commonly accepted methods and procedures. A subset of measurements were repeated on a conventional C-arm LINAC (TrueBeam and Trilogy, Varian Medical System) for comparison. Clinical patient images of pelvic and abdominal regions are also presented for qualitative assessment as part of a feasibility study for clinical implementation.
resultsImage acquisition time was 17-42 s on the Halcyon system compared with 60 s on the C-arm LINAC systems. The kV imager projection offset, imaging and treatment isocenter coincidence and the couch three-dimensional match movement all achieved less than1 mm mechanical accuracy. All major image quality metrics were within either the national guideline or vendor-recommended tolerances. The designed surrogate approach with the QUART phantom showed a range of 0.24-0.35 cycles/mm for spatial resolution, a contrast-to-noise ratio (CNR) of 2-20 for FDK reconstruction and a tolerance of 0.5 mm for slice thickness. Other metrics derived from the Catphan images obtained on the Halcyon and C-arm LINACs showed comparable values for the FDK reconstruction. The iterative reconstruction tended to reduce noise, as evidenced by a higher CNR ratio. The fast scan pelvis protocols for Halcyon resulted in 50% lower dose compared to the standard scans, and the thorax fast protocol similarly delivered 10% lower dose than the standard thoracic scan. Preliminary patient images indicated that rapid kV CBCT with breath-hold is feasible, with improved imaging quality compared to free-breathing scans.
conclusionIndependent and comprehensive characterization of the kV imaging guidance system on the Halcyon 2.0 system demonstrated acceptable image quality for clinical use. The imaging unit onboard the Halcyon meets vendor specifications and satisfies requirements for routine clinical use. The fast kV imaging system enables the potential for volumetric CBCT acquisition during a single breath-hold and the iterative reconstruction tends to reduce the noise therefore has the potential to improve the CNR for normal size patient.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.