Evidence map›Paper›PMID 30675345›Full record

ArticleLight, science & applications2019

Real-time high-resolution mid-infrared optical coherence tomography.

Niels M Israelsen, Christian R Petersen, Ajanta Barh, Deepak Jain, Mikkel Jensen, Günther Hannesschläger, Peter Tidemand-Lichtenberg, Christian Pedersen, Adrian Podoleanu, Ole Bang

Abstract read
In one paragraph

Article in Light, science & applications, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 40 papers.

0numbers the graph read from it
0cells of the map it votes in
40citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

40 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Mid-infrared single-photon 3D imaging.Light, science & applications · 2023
    Article
  14. Far-field super-resolution chemical microscopy.Light, science & applications · 2023
    Review
  15. Review
  16. Article
  17. Article
  18. Upconversion time-stretch infrared spectroscopy.Light, science & applications · 2023
    Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Niels M Israelsen1DTU Fotonik, Technical University of Denmark, 2800 Kgs, Lyngby, Denmark.
Christian R Petersen1DTU Fotonik, Technical University of Denmark, 2800 Kgs, Lyngby, Denmark.ORCID 0000-0002-2883-7908
Ajanta Barh1DTU Fotonik, Technical University of Denmark, 2800 Kgs, Lyngby, Denmark.
Deepak Jain1DTU Fotonik, Technical University of Denmark, 2800 Kgs, Lyngby, Denmark.
Mikkel Jensen1DTU Fotonik, Technical University of Denmark, 2800 Kgs, Lyngby, Denmark.ORCID 0000-0003-1455-6782
Günther Hannesschläger3Research Center for Non-Destructive Testing (RECENDT), Altenberger Straße 69, 4040 Linz, Austria.
Peter Tidemand-Lichtenberg1DTU Fotonik, Technical University of Denmark, 2800 Kgs, Lyngby, Denmark.
Christian Pedersen1DTU Fotonik, Technical University of Denmark, 2800 Kgs, Lyngby, Denmark.
Adrian Podoleanu5Applied Optics Group, School of Physical Sciences, University of Kent, Canterbury, CT2 7NH UK.
Ole Bang1DTU Fotonik, Technical University of Denmark, 2800 Kgs, Lyngby, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The potential for improving the penetration depth of optical coherence tomography systems by using light sources with longer wavelengths has been known since the inception of the technique in the early 1990s. Nevertheless, the development of mid-infrared optical coherence tomography has long been challenged by the maturity and fidelity of optical components in this spectral region, resulting in slow acquisition, low sensitivity, and poor axial resolution. In this work, a mid-infrared spectral-domain optical coherence tomography system operating at a central wavelength of 4 µm and an axial resolution of 8.6 µm is demonstrated. The system produces two-dimensional cross-sectional images in real time enabled by a high-brightness 0.9- to 4.7-µm mid-infrared supercontinuum source with a pulse repetition rate of 1 MHz for illumination and broadband upconversion of more than 1-µm bandwidth from 3.58-4.63 µm to 820-865 nm, where a standard 800-nm spectrometer can be used for fast detection. The images produced by the mid-infrared system are compared with those delivered by a state-of-the-art ultra-high-resolution near-infrared optical coherence tomography system operating at 1.3 μm, and the potential applications and samples suited for this technology are discussed. In doing so, the first practical mid-infrared optical coherence tomography system is demonstrated, with immediate applications in real-time non-destructive testing for the inspection of defects and thickness measurements in samples that exhibit strong scattering at shorter wavelengths.

Identifiers

PMID30675345
PMCPMC6342823

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.