ArticleScientific reports2019

Geometric Determinants of In-Situ Direct Laser Writing.

Andrew C Lamont, Abdullah T Alsharhan, Ryan D Sochol

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
4.3field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 60 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. TOWARD CONTROLLED-RELEASE DRUG DELIVERY MICROCARRIERS ENABLED BY DIRECT LASER WRITING 3D PRINTING.Proceedings. IEEE International Conference on Micro Electro Mechanical Systems · 2024
    Article
  5. FABRICATION OF MULTILUMEN MICROFLUIDIC TUBING FORProceedings. IEEE International Conference on Micro Electro Mechanical Systems · 2024
    Article
  6. Article
  7. Article
  8. [Biomedical applications of bionic untethered micro-nano robots].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2021
    Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. 3D Printed Microfluidics.Annual review of analytical chemistry (Palo Alto, Calif.) · 2020
    Review
  16. Article
  17. Article
  18. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Andrew C LamontDepartment of Mechanical Engineering, 2147 Glenn L. Martin Hall, University of Maryland, College Park, MD, 20740, USA.
Abdullah T AlsharhanDepartment of Mechanical Engineering, 2147 Glenn L. Martin Hall, University of Maryland, College Park, MD, 20740, USA.
Ryan D SocholDepartment of Mechanical Engineering, 2147 Glenn L. Martin Hall, University of Maryland, College Park, MD, 20740, USA. rsochol@umd.edu.
University of Maryland, College Park · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Direct laser writing (DLW) is a three-dimensional (3D) manufacturing technology that offers significant geometric versatility at submicron length scales. Although these characteristics hold promise for fields including organ modeling and microfluidic processing, difficulties associated with facilitating the macro-to-micro interfaces required for fluid delivery have limited the utility of DLW for such applications. To overcome this issue, here we report an in-situ DLW (isDLW) strategy for creating 3D nanostructured features directly inside of-and notably, fully sealed to-sol-gel-coated elastomeric microchannels. In particular, we investigate the role of microchannel geometry (e.g., cross-sectional shape and size) in the sealing performance of isDLW-printed structures. Experiments revealed that increasing the outward tapering of microchannel sidewalls improved fluidic sealing integrity for channel heights ranging from 10 μm to 100 μm, which suggests that conventional microchannel fabrication approaches are poorly suited for isDLW. As a demonstrative example, we employed isDLW to 3D print a microfluidic helical coil spring diode and observed improved flow rectification performance at higher pressures-an indication of effective structure-to-channel sealing. We envision that the ability to readily integrate 3D nanostructured fluidic motifs with the entire luminal surface of elastomeric channels will open new avenues for emerging applications in areas such as soft microrobotics and biofluidic microsystems.

Identifiers

PMID30674934
PMCPMC6344532
OpenAlexW2912814868

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.