ArticleKorean journal of radiology2019
Analysis of Complications of Percutaneous Transthoracic Needle Biopsy Using CT-Guidance Modalities In a Multicenter Cohort of 10568 Biopsies.
Article in Korean journal of radiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. It is linked to trial NCT07772479 (Comparative Study of Rotational Cryobiopsy Needle and Automated Biopsy Needle in Transthoracic Needle Biopsy for the Diagnosis of Peripheral Pulmonary Lesions), which is not on this map. Cited by 37 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Comparative Study of Rotational Cryobiopsy Needle and Automated Biopsy Needle in Transthoracic Needle Biopsy for the Diagnosis of Peripheral Pulmonary Lesions
Who cites it
37 citing papers in PubMed, 5 syntheses or guidelines pooled it, 75 citations in OpenAlex.
- Autologous blood patch intraparenchymal injection reduces the incidence of pneumothorax and the need for chest tube placement following CT-guided lung biopsy: a systematic review and meta-analysis.European journal of medical research · 2024Pooled it
- Risk factors for air embolism following computed tomography-guided percutaneous transthoracic needle biopsy: a systematic review and meta-analysisDiagnostic and interventional radiology (Ankara, Turkey) · 2023Pooled it
- Tissue Adequacy and Safety of Percutaneous Transthoracic Needle Biopsy for Molecular Analysis in Non-Small Cell Lung Cancer: A Systematic Review and Meta-analysis.Korean journal of radiology · 2021Pooled it
- Incidence, risk factors, and prognostic indicators of symptomatic air embolism after percutaneous transthoracic lung biopsy: a systematic review and pooled analysis.European radiology · 2021Pooled it
- 2020 Clinical Practice Guideline for Percutaneous Transthoracic Needle Biopsy of Pulmonary Lesions: A Consensus Statement and Recommendations of the Korean Society of Thoracic Radiology.Korean journal of radiology · 2021Guideline
- [Application of Rapid HE Staining in Cytological Rapid On-site Evaluation of Peripheral Lung Cancer Needle Biopsy].Zhongguo fei ai za zhi = Chinese journal of lung cancer · 2023Trial
- Trans-osseous coaxial biopsy for pulmonary lesions under CT guidance: Technical efficacy for challenging location.European journal of radiology open · 2026Article
- Determinants of Pneumothorax and Alveolar Hemorrhage After CT-Guided Lung Biopsy.Diagnostics (Basel, Switzerland) · 2026Article
- Efficacy of Portable Ultrasonography for Early Detection of Pneumothorax Following Lung Biopsy.Tuberculosis and respiratory diseases · 2025Article
- The clinical performance of robotic assisted navigation system versus conventional freehand technique for percutaneous transthoracic needle biopsy.Scientific reports · 2025Article
- Case Report: Empyema secondary to percutaneous transthoracic needle biopsy in three cases.Frontiers in medicine · 2025Article
- CT-Guided Transthoracic Core-Needle Biopsy of Pulmonary Nodules: Current Practices, Efficacy, and Safety Considerations.Journal of clinical medicine · 2024Review
- The nodule-pleura relationship affects pneumothorax in CT-guided percutaneous transthoracic needle biopsy: avoiding to cross pleural tail sign may reduce the incidence of pneumothorax.BMC pulmonary medicine · 2024Article
- Effect of smoking on the diagnostic results and complication rates of percutaneous transthoracic needle biopsy.European radiology · 2024Article
- Computed-Tomography-Guided Lung Biopsy: A Practice-Oriented Document on Techniques and Principles and a Review of the Literature.Diagnostics (Basel, Switzerland) · 2024Review
- Impact of Respiratory Phase during Pleural Puncture on Complications in CT-Guided Percutaneous Lung Biopsy.Journal of the Korean Society of Radiology · 2024Article
- [Clinical Application of Robotic Assisted Bronchoscopy in Peripheral Pulmonary Nodule Biopsy].Zhongguo fei ai za zhi = Chinese journal of lung cancer · 2024Review
- Incidence and risk factors for pulmonary hemorrhage after percutaneous CT-guided pulmonary nodule biopsy: an observational study.Scientific reports · 2024Observational
- Pneumothorax after percutaneous CT-guided lung nodule biopsy: a prospective, multicenter study.Quantitative imaging in medicine and surgery · 2024Article
- Repeat biopsy versus initial biopsy in terms of complication risk factors and clinical outcomes for patients with non-small cell lung cancer: a comparative study of 113 CT-guided needle biopsy of lung lesions.Frontiers in oncology · 2024Article
Corrections and comments
- Erratum issued
Authors and funding
13 authors at 9 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo analyze the complications of percutaneous transthoracic needle biopsy using CT-based imaging modalities for needle guidance in comparison with fluoroscopy in a large retrospective cohort. MATERIALS AND
methodsThis study was approved by multiple Institutional Review Boards and the requirement for informed consent was waived. We retrospectively included 10568 biopsies from eight referral hospitals from 2010 through 2014. In univariate and multivariate logistic analyses, 3 CT-based guidance modalities (CT, CT fluoroscopy, and cone-beam CT) were compared with fluoroscopy in terms of the risk of pneumothorax, pneumothorax requiring chest tube insertion, and hemoptysis, with adjustment for other risk factors.
resultsPneumothorax occurred in 2298 of the 10568 biopsies (21.7%). Tube insertion was required after 316 biopsies (3.0%), and hemoptysis occurred in 550 cases (5.2%). In the multivariate analysis, pneumothorax was more frequently detected with CT {odds ratio (OR), 2.752 (95% confidence interval [CI], 2.325-3.258),
conclusionHemoptysis occurred less frequently with CT-based guidance modalities in comparison with fluoroscopy. Although pneumothorax requiring chest tube insertion showed a similar incidence, pneumothorax was more frequently detected using CT-based guidance modalities.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.