Evidence map›Paper›PMID 30662581›Full record

ArticleJournal of medical devices2019

A Hand-Held Device to Apply Instrument-Assisted Soft Tissue Mobilization at Targeted Compression Forces and Stroke Frequencies.

John B Everingham, Peter T Martin, Trevor J Lujan

Open access · bronzeAbstract read
In one paragraph

Article in Journal of medical devices, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

John B EveringhamDepartment of Mechanical and Biomedical Engineering, Boise State University, 1910 University Drive, Boise, ID 83725-2085.
Peter T MartinDepartment of Mechanical and Biomedical Engineering, Boise State University, 1910 University Drive, Boise, ID 83725-2085.
Trevor J LujanDepartment of Mechanical and Biomedical Engineering, Boise State University, 1910 University Drive, Boise, ID 83725-2085 e-mail: trevorlujan@boisestate.edu.
Boise State University · US

Funding

Women's health: interplay of maternal diet and key demographics on neurological health in the rural frontier and remote WestP20GM103408 · NIGMS · UNIVERSITY OF IDAHO · PI Carolyn Hovde Bohach · 2012 to 2026
$59.8M
VPS35 D620N inhibits autophagy through disrupted hyaluronic acid-CD44 signalingP20GM109095 · NIGMS · BOISE STATE UNIVERSITY · PI OXFORD, JULIA THOM · 2014 to 2023
$22.7M
PAR04-122, Extramural Research Facilities Construction:*C06RR020533 · NCRR · BOISE STATE UNIVERSITY · PI RUDIN, MARK JOSEPH · 2010 to 2010
$4.0M
NCRR NIH HHS C06 RR020533NIGMS NIH HHS P20 GM103408NIGMS NIH HHS P20 GM109095
6 · The paper itself

Abstract

Instrument-assisted soft tissue mobilization (IASTM) is a manual therapy technique that is commonly used to treat dysfunctions in ligaments and other musculoskeletal tissues. The objective of this study was to develop a simple hand-held device that helps users accurately apply targeted compressive forces and stroke frequencies during IASTM treatments. This portable device uses a force sensor, tablet computer, and custom software to guide the application of user-specified loading parameters. To measure performance, the device was used to apply a combination of targeted forces and stroke frequencies to foam blocks and silicone pads. Three operators using the device applied targeted forces between 0.3 and 125 N with less than 10% error and applied targeted stroke frequencies between 0.25 and 1.0 Hz with less than 3% error. The mean error in applying targeted forces increased significantly at compressive forces less than 0.2 N and greater than 125 N. For experimental validation, the device was used to apply a series of IASTM treatments over three-weeks to rodents with a ligament injury, and the targeted compressive force and stroke frequency were repeatedly applied with an average error less than 5%. This validated device can be used to investigate the effect of IASTM loading parameters on tissue healing in animal and human studies, and therefore can support the optimization and adoption of IASTM protocols that improve patient outcomes.

Indexed as

IASTMmanual therapymassagemechanotransductionmedial collateral ligamenttendinopathy

Identifiers

PMID30662581
PMCPMC6298531
OpenAlexW2896515919

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.