Evidence map›Paper›PMID 30662087›Full record

ArticleJournal of dynamic systems, measurement, and control2018

Design of a Tri-Axial Force Measurement Transducer for Plantar Force Measurements.

Weizi Li, Roberto Dugnani

Abstract read
In one paragraph

Article in Journal of dynamic systems, measurement, and control, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Weizi LiJiao Tong University Joint Institute, University of Michigan-Shanghai, Shanghai 200240, China e-mail: patronum1991@sjtu.edu.cn.
Roberto DugnaniJiao Tong University Joint Institute, University of Michigan-Shanghai, Shanghai 200240, China e-mail: roberto.dugnani@sjtu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transducers for spatial plantar force measurements have numerous applications in biomechanics, rehabilitation medicine, and gait analysis. In this work, the design of a novel, tri-axial transducer for plantar force measurements was presented. The proposed design could resolve both the normal and the shear forces applied at the foot's sole. The novelty of the design consisted in using a rotating bump to translate the external loads into axial compressive forces which could be measured effectively by conventional pressure sensors. For the prototype presented, multilayer polydimethylsiloxane (PDMS) thin-film capacitive stacks were manufactured and used as sensing units, although in principle the design could be extended to various types of sensors. A quasi-static analytic solution to describe the behavior of the transducer was also derived and used to optimize the design. To characterize the performance of the transducer, a 3 cm diameter, 1 cm tall prototype was manufactured and tested under various combination of shear and normal loading scenarios. The tests confirmed the ability of the transducer to generate strong capacitive signals and measure both the magnitude and direction of the normal and shear loads in the dynamic range of interest.

Indexed as

diagnosticgait analysisPDMSplantar forcepressuresensorsheartransducer

Identifiers

PMID30662087
PMCPMC6262213

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.