ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2019
Fetal hemodynamics and cardiac streaming assessed by 4D flow cardiovascular magnetic resonance in fetal sheep.
Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed, 71 citations in OpenAlex.
- Role of α-adrenergic activation during the hemodynamic response to maternal hyperoxygenation in fetal sheep†.Biology of reproduction · 2026Article
- Fetal glucose availability: a key regulator of the metabolic, hormonal and contractility profiles of the fetal sheep heart.The Journal of physiology · 2026Article
- α-Adrenergic blockade impairs ductus venosus shunting during an acute period of fetal hypoxaemia without further deficits to cerebral oxygen delivery.Experimental physiology · 2026Article
- The hypoxic fetus as a patient: adaptations to the intrauterine environment.Philosophical transactions of the Royal Society of London. Series B, Biological sciences · 2025Review
- Feasibility of multimodal magnetic resonance imaging to assess maternal hyperoxygenation in sheep pregnancy.The Journal of physiology · 2025Article
- Reliability of 4D Flow MRI for Investigation of Fetal Cardiovascular Hemodynamics in the Third Trimester.Radiology. Cardiothoracic imaging · 2024Article
- Maternal tadalafil treatment does not increase uterine artery blood flow or oxygen delivery in the pregnant ewe.Experimental physiology · 2024Article
- Acute-on-chronic: using magnetic resonance imaging to disentangle the haemodynamic responses to acute and chronic fetal hypoxaemia.Frontiers in medicine · 2024Article
- Utility of Fetal Cardiac Resonance Imaging in Prenatal Clinical Practice: Current State of the Art.Diagnostics (Basel, Switzerland) · 2023Review
- Fetal cardiovascular blood flow MRI: techniques and applications.The British journal of radiology · 2023Review
- Acute resveratrol exposure does not impact hemodynamics of the fetal sheep.Physiological reports · 2023Article
- Recasting Current Knowledge of Human Fetal Circulation: The Importance of Computational Models.Journal of cardiovascular development and disease · 2023Review
- The current state and potential innovation of fetal cardiac MRI.Frontiers in pediatrics · 2023Review
- Advanced imaging of fetal cardiac function.Frontiers in cardiovascular medicine · 2023Review
- Placental MRI Predicts Fetal Oxygenation and Growth Rates in Sheep and Human Pregnancy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022Article
- Structured analysis of the impact of fetal motion on phase-contrast MRI flow measurements with metric optimized gating.Scientific reports · 2022Article
- Open or closed: Changes in ductus arteriosus flow patterns at birth using 4D flow MRI in newborn piglets.Physiological reports · 2021Article
- Maternal hyperoxygenation in congenital heart disease.Translational pediatrics · 2021Review
- The application ofJournal of developmental origins of health and disease · 2021Review
- Cardiac magnetic resonance imaging: insights into developmental programming and its consequences for aging.Journal of developmental origins of health and disease · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 3 institutions in 2 countries.
Funding
Abstract
backgroundTo date it has not been possible to obtain a comprehensive 3D assessment of fetal hemodynamics because of the technical challenges inherent in imaging small cardiac structures, movement of the fetus during data acquisition, and the difficulty of fusing data from multiple cardiac cycles when a cardiac gating signal is absent. Here we propose the combination of volumetric velocity-sensitive cardiovascular magnetic resonance imaging ("4D flow" CMR) and a specialized animal preparation (catheters to monitor fetal heart rate, anesthesia to immobilize mother and fetus) to examine fetal sheep cardiac hemodynamics in utero.
methodsTen pregnant Merino sheep underwent surgery to implant arterial catheters in the target fetuses. Anesthetized ewes underwent 4D flow CMR with acquisition at 3 T for fetal whole-heart coverage with 1.2-1.5 mm spatial resolution and 45-62 ms temporal resolution. Flow was measured in the heart and major vessels, and particle traces were used to visualize circulatory patterns in fetal cardiovascular shunts. Conservation of mass was used to test internal 4D flow consistency, and comparison to standard 2D phase contrast (PC) CMR was performed for validation.
resultsStreaming of blood from the ductus venosus through the foramen ovale was visualized. Flow waveforms in the major thoracic vessels and shunts displayed normal arterial and venous patterns. Combined ventricular output (CVO) was 546 mL/min per kg, and the distribution of flows (%CVO) were comparable to values obtained using other methods. Internal 4D flow consistency across 23 measurement locations was established with differences of 14.2 ± 12.1%. Compared with 2D PC CMR, 4D flow showed a strong correlation (R
conclusionsThe combination of fetal surgical preparation and 4D flow CMR enables characterization and quantification of complex flow patterns in utero. Visualized streaming of blood through normal physiological shunts confirms the complex mechanism of substrate delivery to the fetal heart and brain. Besides offering insight into normal physiology, this technology has the potential to qualitatively characterize complex flow patterns in congenital heart disease phenotypes in a large animal model, which can support the development of new interventions to improve outcomes in this population.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.