ArticleLasers in medical science2019
Impact of lens density and lens thickness on cumulative dissipated energy in femtosecond laser-assisted cataract surgery.
Article in Lasers in medical science, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 16 citations in OpenAlex.
- Conventional Phacoemulsification Surgery Versus Femtosecond Laser Phacoemulsification Surgery: A Comparative Analysis of Cumulative Dissipated Energy and Corneal Endothelial Loss in Cataract Patients.Clinical ophthalmology (Auckland, N.Z.) · 2023Trial
- Characteristics and Factors of Incision-Related Descemet Membrane Detachment During Cataract Surgery: A Prospective Study.Ophthalmology and therapy · 2026Article
- Cumulative Dissipated Energy (CDE) in Three Phaco-Fragmentation Techniques for Dense Cataract Removal.Clinical ophthalmology (Auckland, N.Z.) · 2023Article
- Comparison of ultrasound phacoemulsification and FemtoMatrixFrontiers in medicine · 2023Article
- Cataract Grade and Pupil: Comparison Between Conventional Phacoemulsification and Low-Energy Femtosecond Laser Assisted Cataract Surgery.Clinical ophthalmology (Auckland, N.Z.) · 2023Article
- Femtosecond Laser-Assisted Cataract Surgery: Analysis of Surgical Phases and Comparison with Standard Phacoemulsification in Uncomplicated Cataracts.Vision (Basel, Switzerland) · 2022Article
- Correlation Between Degree of Lens Opacity and the Phacoemulsification Energy Parameters Using Different Imaging Methods in Age-Related Cataract.Translational vision science & technology · 2022Observational
- An Assessment of Cataract Severity Based on Antioxidant Status and Ascorbic Acid Levels in Aqueous Humor.Antioxidants (Basel, Switzerland) · 2022Article
- Comparison of visual outcomes after bilateral implantation of two intraocular lenses with distinct diffractive optics.Clinical ophthalmology (Auckland, N.Z.) · 2019Article
- Lens Thickness in Infants and Children with Cataracts.Ophthalmology scienceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To evaluate the required cumulative dissipated energy (CDE) to fragment the crystalline lens in femtosecond laser-assisted cataract surgery (FLACS) in relation to lens density and lens thickness. Consecutive eyes that underwent FLACS between September 2014 and March 2017 by a single surgeon using in all cases the same femtosecond laser and phacoemulsification platform were included in our retrospective study. Prior to surgery, corrected distance visual acuity (CDVA), optical biometry corneal, and crystalline lens tomographies were performed to assess anterior chamber depth (ACD), axial length (AL), and crystalline lens parameters (i.e., lens density, thickness, and nucleus staging (NS)). After surgery, CDE was calculated and analyzed in relation to lens density (LD) and lens thickness (LT). Zero ultrasound expenditure cases were recorded and their occurrence analyzed. The chart review identified 236 eyes of 200 patients, 98 males and 102 females aged 65± 15 years which were included in the study. Mean LD was 11.26 ± 2.05 pixel intensity units (range 7.30-18.80), and the mean LT was 3417 ± 405.17 μm (range 2545-4701). LD and LT correlated moderately (r = 0.50, p < 0.001) and weakly (r = 0.23, p < 0.001), with post-laser CDE. Higher LD and LT were also associated with lower rates of zero phaco (eyes in which no phacoemulsification energy was necessary). Furthermore, NS (r = 0.528, p < 0.001) and CDVA (r = - 0.3524, p < 0.001) also correlated with CDE. Higher LD, LT, NS values, and low CDVA are associated with higher ultrasound expenditure (CDE-cumulative dissipated energy) and with lower rates of zero ultrasound expenditure during FLACS.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.